Came out to find out why that the breaker for a system was tripping. Found that the disconnect was going bad . Replaced the the disconnect.
Troubleshooting a no cooling call on a Ruud heat pump system. Found system locked out on high pressure lockout. Reset power and found outdoor fan motor not coming on. Shut power off and found 70/10 MFD capacitor bad on both compressor side and fan side. Replaced capacitor at warranty price since system is a 2019 and still under manufacturer warranty. No other issues found.
Troubleshooting a water leak at air handler. Found old system with a metal drain pan. Found drain outlet of drain pan clogged and not allowing water to drain, overflowing from pan, down unit onto floor. Took careful time to clean pan and drain as unit is aged. Was able to clean pan and drain outlet to allow good drain flow for system. No other issues found.
A.c checkout on two York affinity systems. Both systems look great at this time.
Pma a.c checkout on new high efficiency lennox heat pump. System looks good at this time.
Came out to find out why water was leaking on a Lennox heatpump. Found that the drain pan was clogged up. Got the pan cleened and made sure that the system was draining.
Working on a Lennox ac that is not cooling due to low refrigerant charge
Came out for planned maintenance agreement cooling tune up on two Lennox heatpumps found that they were both operating properly.
Troubleshooting a no cooling call on a Lennox AC unit. Found outdoor unit coil very dirty, and system running very hot. Coil had no airflow through it. Washed out coil thoroughly. Tested operation after washing and system temperatures and pressures came down to normal levels. No other issues found.
Troubleshooting a no cooling call. Found outdoor unit not coming on. Found 30/5 MFD capacitor swollen and bad. Replaced capacitor with new. Checked system operation. No other issues found.
Came out for a planned maintenance agreement cooling tune up. Checked the system and found that it was operating properly.
Came out to do a ac tune up on Lennox heatpump. Found that the system was low on refrigerant. Added 2 lbs r410a.
Came out for planned maintenance agreement cooling tune up. Found that the system was operating properly.
Doing ac tune ups on a trane system and a carrier heat pump
Working on a Lennox ac that is not working due to a failed high pressure switch