Inspected reverse osmosis system that had a constant leak. Identified issue with RO discharge line which had film over it. Discussed with homeowner about relocating the discharge line, but homeowner opted not to invest in repairs due to planned countertop replacement scheduled for spring.
Diagnosed Carrier furnace failure due to seized blower motor preventing proper heat distribution. Performed system inspection finding severely clogged air filter and verifying functionality of flame sensor, ignitor, and burners. After cycling the furnace, confirmed blower wheel inoperability requiring blower motor replacement. Provided customer with replacement options.
Performed diagnostic inspection on 15-20 year old natural gas forced air furnace following customer's new enrollment in Family Rewards program. Identified and cleared plugged condensate drain that was causing intermittent operation issues as water would accumulate and trigger shutdown until drained. Conducted comprehensive maintenance including heat exchanger inspection and electrical component testing with multimeter verification. Replaced aging thermostat with difficult buttons. System now operating normally with proper drainage.
Repaired a leak in the domestic cold water system originating from a 90-degree fitting after the water meter. Removed the faulty fitting, then re-sweated a new 90-degree fitting to restore proper system operation.
Responded to emergency service call to address main water line leak in basement. Successfully replaced faulty valve before the water meter after city water shutdown. Additionally, removed old saddle valve under kitchen sink and installed new valve for refrigerator icemaker connection, restoring proper water supply to both systems.
Temporarily reinstalled customer's toilet with new wax seal and proper shimming following previous flooding incident and remediation work. Confirmed proper function of recently purchased toilet components. Customer advised this is an interim installation, with future service required for toilet removal during flooring replacement and final reinstallation once flooring work is complete.
Responded to no-heat call for 4-year-old furnace with reported flashing red light and ignition issues. Upon arrival, furnace was operating normally. Performed comprehensive diagnostic testing using Fluke 365 True RMS Clamp Meter on electrical components and inspected ignition system. Checked pressure switch, hot surface ignitor, and gas valve functionality. Examined blower motor assembly and verified proper gas line connections. Cleaned and replaced air filter to ensure optimal airflow. No immediate concerns identified; system functioning properly at completion of service.
Responded to no heat complaint on 5-year-old Goodman furnace. Diagnostic inspection revealed furnace attempting to ignite (clicking) but failing to maintain flame. Identified corroded flame sensor and signs of rust in cabinet, though no active leaks were present. Successfully replaced flame sensor, restoring normal heating function.
Responded to service call regarding "needs maintenance" alert displayed on Bryant thermostat following routine maintenance performed in August. Verified system was operating correctly with no active faults. Explained to homeowner that the notification was a standard reminder for scheduled maintenance rather than an operational issue. Reset maintenance reminder on thermostat.
Performed comprehensive furnace tune-up service including correction of gas train pressure from 3.671 inWC to 3.30 inWC and clearing of condensate drain line and trap that contained accumulated spiderwebbing and debris. Verified proper operation of all critical components (inducer motor, capacitor, pressure switch, control board connections, and thermostat), confirmed moderate condition of return air filter, and documented combustion CO at 18 ppm, with furnace now operating normally with no immediate concerns.
Responded to no heat complaint for 25+ year old furnace that was cycling without ignition. Bypassed furnace control board temporarily to restore heating function. Upon removing bypass clippers, unit continued to operate normally. Performed comprehensive diagnostics including gas pressure verification, carbon monoxide testing, and heat exchanger inspection with no hazardous conditions found. Cleaned flame sensor and checked pressure switch and flame rollout switches. Discovered extremely dirty furnace filter clogged with pet fur and dirt causing airflow restriction. Educated homeowner on proper filter maintenance, condensation trap cleaning, and keeping furnace area clear of obstructions. Unit now functioning properly.
Responded to no heat call for 3-year-old LP furnace. Diagnosed low pressure switch stuck in closed position. Replaced faulty pressure switch, verified complete system operation was restored, and confirmed all other components were functioning properly.
Performed annual maintenance on gas furnace, confirming system is operational with no issues identified. Inspected control board and electrical connections to ensure proper function. Additionally, secured and capped off gas line as requested by customer.
Performed comprehensive inspection of 20-year-old Rheem Performance water heater and associated plumbing system. Evaluated three outdoor spigots requiring replacement. Documented current installation conditions including supply lines, drainage configuration, and connection points. Provided customer with detailed replacement options and repair estimates for multiple plumbing projects as requested.
Diagnosed and resolved low hot water pressure at kitchen faucet caused by sediment accumulation in the plumbing lines. Installed whole-house sediment filter to address ongoing water quality issues from the customer's well water system, effectively restoring proper flow to both hot and cold water sides of the kitchen faucet.