Performed prepaid tuneup. Changed owners 20x25x4 filter. 75/5 capacitor okay. Amp draws and drains okay. Looking for a 15 degree sc. was 20 degrees . Cleaned and run test. All okay at this time. Thanks Mark and Paul.
Performed three air conditioner tuneups, and replaced batteries on two thermostats. All equipment is operating properly at this time. Thanks!
Furnace clean and check 16x25x4 air filter ok . Ran test on unit and found all to be ok at this time . Nat gas HSI 48.5 Draft inducer amps .24 Blower amps 1.87 Gas IWC 1.5 to 3.5 Temps RA 60 SA 106 Co 33 Jay
Clean and check 1st fl and 2nd fl furnaces. Filters to be replaced by owner. Both units running good at this time. Pulled and cleaned washable filter on Aprilaire dehumidifier. 1st fl Hsi 51.7 Inducer amps .63 Blower amps 2.13 Co .28 Return air 64 Supply air 114 Gas 3.5 variable 2nd fl Hsi 47.6 Inducer amps .58 Blower amps 1.08 Co 18 Return air 66 Supply air 97 Gas 3.5 variable Thanks Paul