Heating System Repair: Responded to no-heat call. Inspected hot surface ignitor, flame sensor, and gas valve operation. Found ignitor cracked and failing to glow consistently. Replaced ignitor, tested ignition sequence and gas valve response, and verified reliable ignition and heating through multiple cycles.