1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Local Reviews
for dallastown, pa

Rated 5.0 out of 5 stars based on 1 customer reviews

friendly techs , great service


Response from K&D Factory Service Inc.:

We appreciate the great review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dallastown, pa

Ashley B.

Ashley B. Job Checkin

Commercial Coffee Machine Repair. I was called by a client in need of repairs on their commercial coffee machines. I arrived and discovered limescale buildup. A thorough descaling process ensured the machines consistently brewed coffee for the client’s business.


Ashley B.

Ashley B. Job Checkin

Commercial Exhaust Fan Repair: In response to a malfunctioning exhaust fan, I performed a swift replacement, meticulously addressing the issue to ensure proper ventilation. This not only aimed at creating a comfortable and safe kitchen environment but also involved enhancing the fan's efficiency in effectively removing heat, smoke, and odors. The meticulous replacement procedure contributes to the overall functionality and comfort of the kitchen space.


Ashley B.

Ashley B. Job Checkin

Commercial Salamander Oven Installation. A busy commercial kitchen upgraded with a new salamander oven. Our team efficiently positioned and secured the oven, connected utilities, and ensured even heat distribution. Thorough testing and staff training followed, resulting in an enhanced cooking station that added versatility to the kitchen's operations.


Ashley B.

Ashley B. Job Checkin

Commercial Kitchen Equipment Repair near E Main St. We received a service request from a coffee shop that had a malfunctioning espresso machine. After inspecting the machine, I discovered a faulty pump. I replaced the pump and performed tests to ensure the espresso machine was producing quality coffee. The client was relieved to have their espresso machine working again, as it was essential for their business.


Mark B.

Mark B. Job Checkin

Arrived to inspect a water leak. Pulled out the ovens to get behind for closer inspection and found that the main water line hose clamp was loose. Tightened and secured the clamp and verified that the leak was gone.


Service C.

Service C. Job Checkin

Found TRUE Prep Table unit at 55 degrees when I arrived, Checked pressures and found to be low, I added 134A to bring pressures to normal, I checked for leaks and got a hit on the evaporator, The evaporator and cap tube will need to be replaced, customer would like a quote on repair


Service C.

Service C. Job Checkin

Came in and per customer there is noise. when I came in to the store, found the noise is coming from hood system. tried to see if I could find access to the roof but I didn't find any access. went to check next door and they don't have access either. will have to send someone from refrigeration team to come look at the hood system. Found motor on exhaust getting hot then turning off and when cools it starts again, customer wants motor replaced ,Part on order at United York. 11/14/19 Replaced motor on pizza oven exhaust, unit is not cycling on and off any longer, unit is working properly at this time


Service C.

Service C. Job Checkin

Found Pizza Oven thermocouple bad. Replaced thermocouple. Tested. Okay now.


Service C.

Service C. Job Checkin

Found Holding Cabinet wiring incorrect. Wired correctly. Tested, found ready to use.


Service C.

Service C. Job Checkin

Reach-In Freezer unit was at 25 degrees when I arrived, found condenser coil very dirty, blew out condenser with nitrogen and used coil cleaner to remove grease, unit at 10 degrees when I left and unit is working properly at this time


Service C.

Service C. Job Checkin

On Walk-In Cooler, found time delay on condenser unit bad, picked one up locally and replaced, unit coming down to temperature and is working properly at this time ****mileage and travel on work order #185841*** Unit was in defrost and temperature is dropping again and working properly


Service C.

Service C. Job Checkin

Found Prep Table unit low on refrigerant, Dropped refrigerant left in system and recharged with factory amount of 134A, I checked for leaks in evaporator with leak detector and found none, I also checked for leaks at condenser and found none until I removed my gauges, found high side service valve leaking, I tightened shrader valve and the leak stopped, unit got down to temperature and cycled off,unit is working properly at this time.


Service C.

Service C. Job Checkin

Replaced Convection on/off switch. Ran unit, found ready to use.


Service C.

Service C. Job Checkin

Found temp for Reach In Cooler for Dairy Products going down into 20s degrees. stat would not adjust, installed new stat. Adjusted temp 35 degrees cut out. Charge feels good. Was reported that condenser was making noise, found nothing wrong, They cleaned condenser which could have been the problem.


Service C.

Service C. Job Checkin

All five low boy Prep Table units drain pans can't keep up. They have no wicks in pans. Called true to see if they can be retro fitted. Was on hold for a while so I left a message. 07/27/18 Installed new wicks in 5 low boys.