1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Local Reviews
for dunmore, pa

Rated 4.5 out of 5 stars based on 2 customer reviews

Super Guys!

The K & D Team of repairman are super!. always courteous, friendly and get the job done right! Answer my questions and never a surprise cost.


Response from K&D Factory Service Inc.:

We are pleased to know your experience with us was a good one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable and great service

The people at K & D were very helpful and addressed our needs quickly and repaire's were done in a timely manner.


Response from K&D Factory Service Inc.:

We are pleased to know your experience with us was a good one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dunmore, pa

Service C.

Service C. Job Checkin

examined Heat Lamp unit, breaker shut off. Removed power switch panel and found 20a household On/Off switch and all wiring inside conduit box burnt up. Best course of action would be to replace unit as age is unknown, no model or serial number on unit. Looks to be a crescor but no other information. Unit is 60" 120V. If replacement is not an option, unit will need incoming power wire cut back and stripped, 20a Switch replaced, Wire going to elements from switch replaced. Wires look to be 10 gauge. Power to unit is currently off and should not be switched back on. Closing out this work order.


Service C.

Service C. Job Checkin

Found Gas Fryer first vat on left would not cycle on, computer blank - removed panels, have 12 volts and 24 volts at interface board unplugged computer wire harness and put Bach in computer lite and cycled on unit part number on computer (controller 1086212 item number 1085777 ) Unit came up to temp - will get price on computer controller Note: controller is no longer available, called and left message for customer. Closing out work order.


Service C.

Service C. Job Checkin

Middle oven pilot on, no gas coming through for burner, safety button stuck and always letting pilot gas through. Replaced safety and thermocouple, tested.


Service C.

Service C. Job Checkin

Examined Hot Well unit. Found 2=212081=THERMOSTAT,ELECTRIC KA604 #KA6 - 5=223590= knob Customer requests 5 knobs and two thermostat knob rods are broken so whole thermostat needs replacement. 4-3-19 Replaced all five knobs and 4th and 5th thermostat from right. Tested okay.


Service C.

Service C. Job Checkin

Found electric Fryer unit on and working, customer advised that unit shut off and would no cycle back and controller was blank - switched control to unit to left. If problems goes to left fryer will need control, if problems stay in right vat, maybe power/relay board.


Service C.

Service C. Job Checkin

Examined Dishwasher unit rinse temps are good wash temp is good pressure gauge not working on water line rinse solenoid opening hot water getting by during wash and ran several cycles and none were the same on normal wash times from 48 sec to almost 4 mins. unit leaking were rinse line goes thru top will need to tighten. 3/11/19 Replaced water solenoid valve and pressure gauge tightened leaky fitting on rinse feed, replaced timer filled unit brought to temp ran several cycles all around 45 wash and 15 rinse all okay


Service C.

Service C. Job Checkin

Found Warming Cabinet units thermostat is bad, one side is a Robert Shaw thermostat (1) 5000-814, need knob to match thermostat. Unit is aTraulsen model number n/a 1-25-19 Replaced thermostat and knob, tested drawing 5 amps unit working, finished assembly all okay.


Service C.

Service C. Job Checkin

Examined Grill unit, found far left thermostat stem mangled. Straightened out and tested. Found valve seized and knob also ruined from trying to turn on seized valve. Customer stated unit cycles off and goes into a bypass but recently stopped. GS style thermostats don't have a bypass. Spoke with Anthony. advised we will return with surface tester to make sure other thermostats are functioning properly. 1-16-19 Removed and replaced far left thermostat. Checked all 4 thermostats for calibration, all 4 thermostats within 10 degree of each other. Good to go, will part sale knob