Ashley B.

Ashley B. Job Checkin

Commercial Pizza Oven Installation. A pizzeria wanted to upgrade its menu with a new commercial pizza oven. We positioned the oven, connected the gas line and electrical wiring, and fine-tuned the temperature controls. Thorough tests ensured consistent pizza baking results, and the kitchen staff received training in operation and maintenance.


Mark B.

Mark B. Job Checkin

Arrived on,7-10-23- Giuliano G/Ron F-Drain needs re piped and unit needs cleaned/sanitized. Will find parts locally for drain when we come back for cleaning. Both ice machines need cleaned and repiped with 2 inch gap per codes. Returned on, 7-21-23- Giuliano G-Replaced water lines inside first floor ice machine and repiped drain to code specifications. Cleaned lines and sanitized. Ran ice machine for about 45 minutes to verify proper operation. First floor ice machine is running and up to code. Recommended getting some type of floor blocks so ice machine won’t move. Will need to come back with 3/4inch cpvc for employees ice machine to be repiped to code specifications and clean out ice tray and lines with sanitizer. Also employee mentioned they have a 3rd ice machine that may need serviced as well. Will return on latter date to finish other two ice machines. Completed on, 7-26-23- Giuliano G-Came back to repipe and sanitize employee ice machine. Maintenance must of repiped drains in


Mark B.

Mark B. Job Checkin

Arrived on, 7-10-23- Giuliano G/Ron F-Drain needs re piped and unit needs cleaned/sanitized. Will find parts locally for drain when we come back for cleaning. Both ice machines need cleaned and repiped with 2 inch gap per codes.Returned on, 7-21-23- Giuliano G-Replaced water lines inside first floor ice machine and repiped drain to code specifications. Cleaned lines and sanitized. Ran ice machine for about 45 minutes to verify proper operation. First floor ice machine is running and up to code. Recommended getting some type of floor blocks so ice machine won’t move. Will need to come back with 3/4inch cpvc for employees ice machine to be repiped to code specifications and clean out ice tray and lines with sanitizer. Also employee mentioned they have a 3rd ice machine that may need serviced as well. Will return on latter date to finish other two ice machines. Finished on, 7-26-23- Giuliano G-Came back to repipe and sanitize employee ice machine. Maintenance must of repiped drains in b


Mark B.

Mark B. Job Checkin

Commercial Kitchen Equipment Repair Service. Arrived at the location on 4/28/23 to check over their commercial kitchen equipment that required repairs- Checked over the unit. Found screws on the adjustment for the knob were loose. Secured and calibrated unit. Found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 1/5/23 - Checked over unit. Found when powered on unit starts cycle. Upon checking found cycle switch bad sending unit into cycles one right after the other. Found due to cycling as it was unit burnt relays on control. Will need to order switch and control. Returned to location on 1/10/23 - Replaced all parts unit comes on and is working properly.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/12/22 - Customer explained unit not cooling and at 55°F. Found unit has leak on Johnson low pressure control on condenser. Will return tomorrow to replace and verify no other leaks. Returned to location on 7/13/22 - Replaced low pressure control and filter drier. Verified no leaks and pulled vacuum under 500 microns. Charged with 8lbs of R404a refrigerant. Verified proper operation. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/5/22 - Checked over unit. Found heated ro 325 with no issues. Customer stated unit worked fine until they set it at 300. Had customer set at 300. Noticed the heat was randomly coming on. Upon checking found potentiometer and control are needed. Will order and return. Returned to location on 7/7/22 - Replaced potentiometer and control. Tested and ran at 250, 300, and 350. All ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/22/22 - Customer explained unit doesn’t run. Replaced thermocouple and verified proper operation. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/13/22 - Replaced casters and verified proper operation. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 5/19/22 - Checked over unit. Found pilot low and thermocouple burnt. Pulled pilot to clean and found it would not go back on due to corrosion on feral and threads on pilot. Will need new pilot and thermocouple ordered. Returned to location on 6/2/22 - Replaced pilot and thermocouple. Checked for leaks and found none. Tested and found all operational at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/1/22 - Checked over unit. Found spark wire exposed at connections and was sparking on the back side of the burner. Secured connection and retested. Found sparks as it should. Let heat to ready and found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 5/19/22 - Door jam gaskets have rips and customer wants replaced. Returned to location on 5/24/22 - Replaced gasket and verified proper seal. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 4/19/22 - Checked over unit found thermopile bad. Replaced and tested. Found when heating, the thermostat would not stop heating. Will need new. Returned to location on 4/21/22 - Replaced thermostat and tested. Found ok at 350 deg F.


Mark B.

Mark B. Job Checkin

Arrived at location on 4/7/22 - Customer explained unit running warm. Showed me frosted and frozen evap coil. Found far right fan motor blade snapped off. Fan blade, motor and door gasket is on order. Thawed out coil and explained unit may frost and freeze again and to keep an eye on it until parts come in. Unit is running at this time. Returned to location on 4/19/22 - Replaced evaporator fan motor and blade. Also replaced door gasket. Verified proper operation. Coil has some ice but customer is out of town and I have no power for heat gun. Will advise customer to thaw out to get to full capacity. Unit temp is at 33°F. No other recommendations at this time. Customer is allowing employee Brandon to sign for them.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/18/22 - Removed old fryer and hooked up new one. Leveled unit and checked operating pressure. Verified pilot in proper range of millivolts. Ran unit and watched it satisfy at 350°F.