Mark B.

Mark B. Job Checkin

Arrived at location on 7/12/22 - Customer explained unit not cooling and at 55°F. Found unit has leak on Johnson low pressure control on condenser. Will return tomorrow to replace and verify no other leaks. Returned to location on 7/13/22 - Replaced low pressure control and filter drier. Verified no leaks and pulled vacuum under 500 microns. Charged with 8lbs of R404a refrigerant. Verified proper operation. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/5/22 - Checked over unit. Found heated ro 325 with no issues. Customer stated unit worked fine until they set it at 300. Had customer set at 300. Noticed the heat was randomly coming on. Upon checking found potentiometer and control are needed. Will order and return. Returned to location on 7/7/22 - Replaced potentiometer and control. Tested and ran at 250, 300, and 350. All ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/22/22 - Customer explained unit doesn’t run. Replaced thermocouple and verified proper operation. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/13/22 - Replaced casters and verified proper operation. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 5/19/22 - Checked over unit. Found pilot low and thermocouple burnt. Pulled pilot to clean and found it would not go back on due to corrosion on feral and threads on pilot. Will need new pilot and thermocouple ordered. Returned to location on 6/2/22 - Replaced pilot and thermocouple. Checked for leaks and found none. Tested and found all operational at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/1/22 - Checked over unit. Found spark wire exposed at connections and was sparking on the back side of the burner. Secured connection and retested. Found sparks as it should. Let heat to ready and found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 5/19/22 - Door jam gaskets have rips and customer wants replaced. Returned to location on 5/24/22 - Replaced gasket and verified proper seal. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 4/19/22 - Checked over unit found thermopile bad. Replaced and tested. Found when heating, the thermostat would not stop heating. Will need new. Returned to location on 4/21/22 - Replaced thermostat and tested. Found ok at 350 deg F.


Mark B.

Mark B. Job Checkin

Arrived at location on 4/7/22 - Customer explained unit running warm. Showed me frosted and frozen evap coil. Found far right fan motor blade snapped off. Fan blade, motor and door gasket is on order. Thawed out coil and explained unit may frost and freeze again and to keep an eye on it until parts come in. Unit is running at this time. Returned to location on 4/19/22 - Replaced evaporator fan motor and blade. Also replaced door gasket. Verified proper operation. Coil has some ice but customer is out of town and I have no power for heat gun. Will advise customer to thaw out to get to full capacity. Unit temp is at 33°F. No other recommendations at this time. Customer is allowing employee Brandon to sign for them.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/18/22 - Removed old fryer and hooked up new one. Leveled unit and checked operating pressure. Verified pilot in proper range of millivolts. Ran unit and watched it satisfy at 350°F.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/7/22 - Found unit would turn on but fan would not spin up. Upon checking found relay burnt and not making connection inside relay. Opened relay and cleaned contacts and had to bend pin inside of the relay to test. Found would heat. Replaced relay with new. Ran unit to verify operations. Found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/3/22 - Customer explained unit satisfies way too early. Found thermostat satisfies at 325°f when set to 350°f. Replaced thermostat and verified accuracy of temperature. Watched it satisfy a few times to make sure no other issues present. All is good at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/1/22 - Calibrated all grills. Found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 2/8/22 - Checked over unit. Found water dripping from farm. Pulled ovens out to get behind units. Pulled side cover and found main water line hose clamp loose. Secured and let run and verified leak is gone. Closed up unit and verified all in working order.


Mark B.

Mark B. Job Checkin

Arrived at location on 1/28/22 - Looked over dishwasher. Found tubing came apart from sanitizer rinse diastolic pump. Had disconnected diastolic pump repair tubing connection with zip ties. Reinserted tubing into pump. Had difficulty trying to prime pump but, got sanitizer to flow. Reassembled pump. Tested dishwasher multiple times working dishwasher properly at this time.