- Proposal one of two - Replace existing 3 HP submersible well pump with a new Pentex submersible pump. Pump delivery wet end TBD. - Install a PID 30 variable frequency drive - Remove and dispose of old well tank - Reconfigure plumbing as required for installation of a new stainless steel tank T assembly - Install 505' of new #8 10/2 flat jacket wire in the well - Replace 504' of galvanized t/c well pipe with new 1.25" galvanized pipe - Install a new 33 gallon WR120 well tank - Install an electronic transducer pressure regulator - Mud mat to the well head and supply lumber bridging sufficient to bridge culvert