Based on the water analytics we propose to address certain water characteristics that are reported as outside of the safe drinking water standards. - Hardness. Install a 64K metered Clack water softener with bypass valves and a WS1filter valve. - Iron. Install an iron filtration system with Katalox Lite media, WS1 filter valve and by pass valves - Install a 4 x 20 filter housing with a 4 x 20 GAC filter insert rated at 5 microns - Methylene Chloride: Install a 3 cubic foot GAC filtration system w WS1 filter valve and bypass valves In combination the systems "may" reduce the TDS and bring it within the standards for consumption. The Methylene Chloride issue is unique and we are researching practical applications for reduction of the characteristics. As such, the solution proposed is subject to change. The characteristic is removed effectively by reverse osmosis and generally speaking RO system on scale are quite expensive to maintain and have a large footprint. The RO solution may