Arrived at location on 12/9/21 - Checked the range and turned on the gas. Lit the top range pilots and burners and all ok. Open the left oven and removed the oven bottom . Can smell gas. Checked the pilot tubing and found a pin hole in it under the tubing cover . Looked but don’t have the size tubing . Need 3/16 tubing. Will have to order and return. Also bring along the compression fittings for the tubing. Will order and return. Returned to location on 1/19/22 - Arrived and made way down to the kitchen at the bottom of the hill. Road is icy. Disassemble the left oven and removed the old tubing and installed the new pilot tubing . Drilled out the screws for the burner cover to get at the fitting on the safety valve. Tighten all down. Turn on gas and lit the pilot . No leaks at the pilot tubing fittings. Turn on the burner and burner lights but then the base safety leaks and flames came out of it at the push button. Now new a base safety . Ok per Patti to order it and replace. Shut of