Mark B.

Mark B. Job Checkin

Arrived at location on 9/2/21 - Checked in with Chef Pete. Checked over right side kettle next to Cleveland steamers. Turned on. Low Water light stays on. Checked sight glass. No water, filled jacket with distilled water, supplied by customer. Filled to half way level in the sight glass. Turned on. Set thermostat all the way up. As per instructions, let pressure get to 5 PSI and pulled on PRV pin to release air. Repeated 4 times. Put in cold water. Pressure dropped and came to 25" Hg. Filled with more cold water and turned on to high. The PRV valve release pin is broken. Chef Pete said to replace the valve. Will obtain. Water came to a rolling boil. Chef Pete verified. Will obtain PRV and return. Returned to location on 9/7/21 - Removed old PRV and installed new. Bled air. Cooled down kettle and it pulled a vacuum. Filled kettle with water and turned on. Heated. Water is boiling. Back in service.


Mark B.

Mark B. Job Checkin

Arrived at location on 8/19/21 - Per Chef Sean replace the hose assy on the kettle. Will order and return. Returned to location on 8/26/21 - Arrived and customer allowed me in and made way to 3rd floor Removed the old filler hose assy and installed the new filler hose assy. Tighten down the whole faucet assy. Turn on the water and test. No leaks and filler assy works properly. In service.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/23/21 - put temp probe inside bottom oven. (Jason said it's the one) unit fired rite up came to 367 then dropped to 345 and came back on. After 30min. temp was less and variance was more. 325 to 330. Burner lit every time. changed controller and temp probe. Retested and temp and variance is good. Settled to 352. Had problem getting screws out for temp probe. Did remove them. Unit is operational job complete.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/18/21 checked the bottom oven and the display comes on and can be set in a cook mode but the start button is not responding. This has been a continuous problem per customer. Encoder or display is acting up. Could not get ahold of Angelopo but no one answers the phone. Want part numbers for display and rinse pump then I took and used in the top oven to get it going for customer. Need parts. Will id and call for approval on repairs. Bottom not in service . Top is ok. Returned to location on 6/23/21 Installed new Rinse Aid Pump and control board(display) on bottom oven. Turned on and let preheat. Pressed Start and oven preheated to 500. Started a cycle and took video of operation. Back in service.


Mark B.

Mark B. Job Checkin

Arrived to location on 6/17/21 and spoke to manager. Opened panel on unit and checked dispenser connections. Had to disassemble front panel and remover dispenser from front panel. Dispenser connections to spouts were both clogged. cleaned each spout thoroughly and reassembled unit. Unit now works to specification. unit back in service.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/17/21 and spoke to manager. Opened panel on unit and checked dispenser connections. Had to disassemble front panel and remover dispenser from front panel. Dispenser connections to spouts were both clogged. Cleaned each spout thoroughly and reassembled unit. Unit now works to specification. unit back in service.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/12/21, Upon arrival noticed a 20inch fan blowing on high directly in burner compartments. Took pic, moved fan. Lit both oven pilots and set to 350. Came to temp and cycled. Cleaned air vent in regulator. Unit is operational job complete.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/2/21, to service tilt skillet. Checked elements for resistance. Getting about 60 ohms on each element. Inspected wires for shorts, found nothing inside the unit. Checked contactors for shorts, found nothing. Traced power plug and found l2 and l3 shorted out inside loom. Cut wires back, stripped and rewired plug. Checked tstat and capillary, they were okay. Need new bulbs for power light and heat indicator. Will obtain and return. Replaced the power switch and the 24 vac light and the temperature knob. Power on and unit heats up and have 12 amp heating. Tested the tilt switch and it shuts off the unit when tilted . Light now works. Back in service.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/7/21 to check on double stacked pizza oven. Found compression nut broken for pilot. Cut off and replaced. Tightened down and lit pilot. It held and burners came on. Came to temp and went into by-pass. Unit is operational job complete.


Service C.

Service C. Job Checkin

Arrived on site and checked in with MOD. customer complained walk in cooler not maintaining temperature. checked condenser and found condenser fan motor is bad. need to replace. will order and return to repair. further diagnostic will be required at that time. 10/7/20 Arrived on site and checked in with MOD. removed and replaced condenser fan motor. ran and tested unit. found system low of R-22 charge. charged system with R-22. ran and tested. unit working properly at this time.


Service C.

Service C. Job Checkin

Found the Under Counter Refrigerator unit off. Turned on and tested. Found the compressor came on but the temperature in the box went up. One of the condenser fans did not work. There was no. heat being taken out of the box. Got a saddle valve and installed it. Found the refrigerant pressure at 0 PSI when on. Leak tested the system. My electronic detector only went off when my detector was put inside the box. The evaporator coil is leaking. Added some refrigerant and the unit started to cool down and cycled off on temperature. Need to quote.


Service C.

Service C. Job Checkin

Found the Under Counter Refrigerator unit off. Turned on and tested. Found the compressor came on but the temperature in the box went up. One of the condenser fans did not work. There was no. heat being taken out of the box. Got a saddle valve and installed it. Found the refrigerant pressure at 0 PSI when on. Leak tested the system. My electronic detector only went off when my detector was put inside the box. The evaporator coil is leaking. Added some refrigerant and the unit started to cool down and cycled off on temperature. Need to quote.


Service C.

Service C. Job Checkin

Checked range and found the rear pilots are all low or out . Tried cleaning them but it did no good . Reassembled and ran ovens to 350° and cycle. Temps calibration ok. Only had to adjust the right oven knob. Left and right ovens ok. All top burners work ok. Soap tested all connections and gas hose and quick connect and burner valves and thermostat lines and no gas leaks anywhere. Gas smell may have come from the pilots being out. Will order new pilot kits and return to replace. Unit in service. 9/4/20 Removed grates and burners. removed pilot assy. on all. replaced them with new. put unit back together and lit pilots. adjusted all and turned burners on 1 at a time. they all lit with pilot. unit is operational job complete.


Service C.

Service C. Job Checkin

arrived onsite to check top Southbend convection oven. checked and found oven not heating. troubleshot and found broken burner igniter. also checked voltage from ignition module, no 24 volts. have voltage to module but no 24volts to igniter. ignition module also bad. checked truck stock for module and igniter, igniter damaged and no module. will need to order, return and replace. customer will start using this kitchen shortly, but not right now. 6/29/20 arrived onsite to repair top Southbend convection oven. accessed surface igniter and ignition module. proceeded and replaced hot surface igniter and ignition module. dressed wiring and brought oven into operation. allowed oven to heat and cycle a few times. oven in operation. Also removed foil impeded in fan blower wheel. foil impeded in wheel will cause uneven heat and hard on motor. oven in operation.


Service C.

Service C. Job Checkin

Upon arrival found burnt wire connection near the compressor and also found restriction on the capillary tube of Prep Table. Repaired the wiring connection and tried to fix the restriction problem on the capillary tube by heating the tubing while flowing nitrogen gas throughout the system. Charged unit to manufacturer's spec. Started the unit and watched unit's operating pressure. Unit still show sign of restriction in the capillary tube, but it is working better than before. Talked to chef and explained what I did and will return to do a follow up next week. 6/15/2020 Returned to do a follow up on the unit. Customer is not on site. Look through the window and found the old unit was replaced by a new unit. I told customer that i have done everything I can to save old unit when i was here the last time. If it is still not cooling properly , then he will needs to buy a new unit. Talked to Rich D and explained everything to him, he said he will adjust the bill later.