They came out the next day while others were backed up much longer. They diagnosed the problem quickly and found some other maintenance items that were needed and were reasonable in addressing those.
Response from All Seasons Comfort Systems LLC:
Thank you so much for this great 5-star review. We really appreciate your business and helping to share the word about All Seasons!
Response from All Seasons Comfort Systems LLC:
Thank you so much for taking the time to leave us a 5-star review!
Response from All Seasons Comfort Systems LLC:
We are incredibly grateful that you took the time out to leave us a 5-Star review.
Very knowledgeable and very friendly
Response from All Seasons Comfort Systems LLC:
We are incredibly grateful that you took the time out to leave us a 5-Star review.
Logan did a very complete job checking our systems. I feel like he went above and beyond and wasn’t in a rush to go to the next job. They worked around our busy schedule and stayed in constant communication. Excellent A+
Zack did a very good job of testing our HVAC systems and thoroughly explained the work that he performed. He is friendly and cheerful and is dependable. Thank you, All Seasons Comfort Systems!
Really enjoyed talking with Zach. Seemed very knowledgable about the product. He was able to answer every question that I posed to him. I asked his opinion on a few different things and recieved what i believe was good information from him. That's why we didn't have to give it a lot of thought in order to go with All Seasons. And best of all he served our Country in the USMC!
Giving a second opinion on a refrigerant leak a previous company couldn’t find. I was able to find 3 leaks on the evaporator coil. No other leaks found across the system. Ordering a replacement evaporator coil under warranty to repair the system from leaks.
Troubleshooting a no AC call where the heat pump is only making heat during a call for AC. Found outdoor unit had multiple dead mice inside, which had chewed through multiple wires on unit. Re-wired system to fix damage wiring. Tested operation. No other issues found.
Identified a malfunctioning blower motor in a Carrier air handler during diagnostics. Replaced the faulty motor to restore proper airflow. Additionally, conducted necessary duct repairs in the attic unit to address airflow restrictions. Ensured all repairs were completed meticulously to optimize the system's performance and efficiency. Advised the homeowner on regular maintenance to prevent future issues.
Changing out a heat kit that is under warranty and running new communication wire to the outdoor heat pump on a Lennox system. This system is now operating properly and working well!
Heating tune up in shell knob on a Lennox variable capacity heat pump and air handler is showing perfect operation!
Doing a Planned Maintenance Agreement heating tune up on a Goodman heat pump package unit. Replacing air filter. Checking coils for cleanliness. Checking blower for cleanliness and operation. Testing 10KW emergency heat strips. Checking temperature split. Tested defrost operation. And tested thermostat operation. Fixed a future problem on wiring that was starting to rub through. Which would have caused the unit to short out and have issue’s operating. Fixed wires and secured away from metal.
Planned maintenance checkout on Rheem heat pump system. System checked out great at this time.
Performing two dual fuel heating checkouts, on a planned maintenance agreement for two Lennox systems. Replacing air filters. Replacing humidifier pad and testing operation. Checking coils for cleanliness. Checking refrigerant charges. Testing electrical components and defrost. Performing combustion analysis’s on furnaces. Checking temp rises. Inspecting burners, flames sensors, and igniters. Checking flue pipes. No issues found on todays checkout.
Working on a temp star heat pump that is not cooling due to a failed capacitor
Working on a Lennox heat pump that is leaking due to a plugged drain
Troubleshooting a no cooling call on an Amana A/C. Found outdoor unit running only the fan and not the compressor. Verified compressor would not start. Disconnected power and checked the 45/5 dual run capacitor. Compressor side (45) had failed, and was bad, causing compressor to not start. Replaced 45/5 capacitor under warranty. Checked amp draws and system operating. System now cooling properly at this time.
Starting a planned maintenance agreement on a Rheem heat pump system. Inspecting air filter, replacing if needed. Washed out outdoor unit and coil, removing leave buildup on bottom of unit. Spraying indoor coil to help remove dirt/debris buildup. Cleaning drain line. Checking refrigerant levels. Testing outdoor electrical components and checking amperage’s. Verifying correct thermostat operation. And checking overall system performance. No issues were found at checkout.
Troubleshooting a Lennox variable capacity communicating heat pump that lost communication with outdoor unit. System showing critical alert and not running. Added 24v transformer to outdoor unit to remedy 12v DC and 24v AC voltage bleed throughs, to eliminate lost communication signal on old thermostat wiring. Tested system after repairs, no issues present.