4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Local Reviews

Rated 4.9 out of 5 stars based on 2478 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Wesley was great, very professional and through! Highly recommend Evan’s for any service, we are happy with the service we get as part of our annual inspection.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service 😊

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Pleasant to deal with. Great work. Would highly recommend the company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Good workers very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Shalik was personable, efficient and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great, friendly service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Joe did great work thanks Joe

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent as always!

Shalik was absolutely excellent. Your technicians are all so fantastic.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Install crew was great, quick, efficient and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Westley was very polite and courteous. He offered great advice on a potential upgrade and didn’t try to oversell anything that wasn’t necessary.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Andrew S.

Andrew S. Job Checkin

Keeprite furnace maintenance and inspection Furnace is working safely and efficiently and in great condition at this time. Found no problems or concerns with the unit during visit. Furnace had been struggling the day before the service call. Found error codes stored in board indicating furnace was shutting down on high limit trips. Old filter was installed a little too long and restricting too much air. Recommend changing those merv 13s every 2 months instead of every 3. Attached PureAirX electronic air cleaner quote. Price includes metal frame and a years supply of filters.


Andrew S.

Andrew S. Job Checkin

Fireplace was not maintaining set temp on thermostat. Customer had been noticing burners dropping out at times during a call for heat. Performed full cleaning of fireplace, cleaned glass. Found small stress fractures in corners of glass. Not quite a crack but definitely something to keep an eye on. After performing maintenance on fireplace it is working well , running consistently and burners are not dropping out. Advised customers to keep an eye on the operation of the fireplace and call us if the problem reoccurs. Office will put together a quote for red tag


Joe P.

Joe P. Job Checkin

Installed furnace


Wesley P.

Wesley P. Job Checkin

Furnace maintenance and inspection. Furnace is in good condition and there are no concerns noted during visit. Client agreed to join comfort club and will consider joining for air conditioner in the spring. Client takes care of humidifier pad, and air exchanger filters.


Wesley P.

Wesley P. Job Checkin

Furnace maintenance and inspection. No concerns noted. Furnace running within spec. Humidifier pad still in good condition. Humidifier operating normally.


Wesley P.

Wesley P. Job Checkin

Appliance: Natural Draft Gas Water Heater Brand / Model: John Wood AV50N 400 Serial Number: 1910114007570 Work Performed: - Completed inspection of the natural draft gas water heater - Verified safe operation, venting, and combustion air provisions - Checked gas connections and overall condition of the appliance Results: - No concerns noted at the time of inspection - Appliance operating normally and within manufacturer specifications - Unit deemed safe for continued operation Inspection & Approval: - Appliance approved by Evan’s Heating and Cooling - Inspected and approved by a licensed gas fitter - Inspection completed


Trevor S.

Trevor S. Job Checkin

Furnace Replacement


Andrew S.

Andrew S. Job Checkin

Goodman furnace repair. Upon arrival burners were cycling on and off repeatedly. Checked flame rod reading, 0.1-0.2ua. Pulled and inspected flame rod, heavy buildup on it. Cleaned off and reinstalled part, checked readings again, 2.0-2.2ua. Furnace is working safely and efficiently at this time. Recommend yearly maintenance on furnace due to age (16 yrs old) Found no other problems or concerns with furnace during service call.


Trevor S.

Trevor S. Job Checkin

Lennox Furnace Installation


Wesley P.

Wesley P. Job Checkin

INVOICE SUMMARY & GAS APPLIANCE INSPECTION REPORT Purpose: Short-Term Rental – Annual Gas Appliance Inspection Overall Inspection Statement: All gas appliances listed below were inspected by a licensed gas technician. At the time of inspection, the appliances were found to be operational and safe for use, with noted items requiring no immediate safety-related repairs. Annual maintenance is required to maintain safe operation and compliance. -------------------------------------------- Fireplace – Upper Level: - Pilot found extinguished on arrival. - Glass removed to access pilot assembly. - Pilot relit using manual ignition. - Fireplace interior cleaned and maintained. - Thermocouple tested and confirmed to be producing a proper signal. - Unit operating normally after service. Status: Approved for Use -------------------------------------------- Fireplace – Main Floor (Front of Home): - Fireplace found in decent overall condition. - Interior cleaned as part of routine maintenance


Shalik M.

Shalik M. Job Checkin

Initial Findings: ​System Status: Thermostat was calling for heat, but the furnace was unresponsive. ​Safety Note: Labeled the furnace service switch for easier identification. ​Error Codes: EE0 (Lockout), EE2 (Pressure Switch Open), and EE5 (Open Fuse). ​Actions Taken: ​Drainage & Seals: Drained accumulated condensation from the inducer motor. Inspected all tubing and secured the pressure switch hosing with a zip tie to ensure a tight seal. ​Pressure Adjustment: Calibrated the low-fire gas pressure from 2.2" wc to the optimal 1.9" wc. ​Testing: Following drainage and pressure adjustments, the furnace was tested and is operating normally (running continuously for 25+ minutes). Required Part: To prevent future moisture buildup, a Westlake drain diverter tee is required. ​Follow-up: We have ordered the part and will schedule the installation with the tenants as soon as it arrives.


Joe P.

Joe P. Job Checkin

Installed furnace and air conditioner


Shalik M.

Shalik M. Job Checkin

Error Code 228: Unable to perform successful pressure switch calibration. Measured suction on pressure switch from collector box - .14 / -1.10"wc. Pressure switch being ordered for swap out.


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Replaced the filter and inspected the Ultraviolet lights. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently


Shalik M.

Shalik M. Job Checkin

Service Performed: System Inspection and Cycle Testing. Status: Resolved / Maintenance Recommendation Provided. ​Technical Observations ​Electrical Inspection: Inspected the furnace control board; identified and tightened loose thermostat terminal connections to ensure signal integrity. ​ Operational Testing: Performed initial test fire with blower doors removed to verify sequence of operation. ​Reinstalled doors and confirmed successful ignition and sustained operation in both Stage 1 and Stage 2 heating cycles. ​Airflow & Limit Diagnostics: * Tested the system using the existing, heavily soiled air filter. ​Results: The furnace experienced a "High Limit" trip (overheating) after approximately 4.5 minutes. Subsequent testing mirrored the client’s reported symptoms, with the unit short-cycling (7 minutes ON / 3 minutes OFF). ​Root Cause: Restricted airflow due to the depleted filter caused internal temperatures to exceed safe operating limits, triggering a safety shutdown. ​Recom