4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Local Reviews

Rated 4.9 out of 5 stars based on 2476 customer reviews

Excellent and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service 😊

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Pleasant to deal with. Great work. Would highly recommend the company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Good workers very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Shalik was personable, efficient and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great, friendly service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Joe did great work thanks Joe

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent as always!

Shalik was absolutely excellent. Your technicians are all so fantastic.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Install crew was great, quick, efficient and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Westley was very polite and courteous. He offered great advice on a potential upgrade and didn’t try to oversell anything that wasn’t necessary.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

A big thank you to Wesley for making our fireplace look brand new!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Shalik M.

Shalik M. Job Checkin

Service Performed: System Inspection and Cycle Testing. Status: Resolved / Maintenance Recommendation Provided. ​Technical Observations ​Electrical Inspection: Inspected the furnace control board; identified and tightened loose thermostat terminal connections to ensure signal integrity. ​ Operational Testing: Performed initial test fire with blower doors removed to verify sequence of operation. ​Reinstalled doors and confirmed successful ignition and sustained operation in both Stage 1 and Stage 2 heating cycles. ​Airflow & Limit Diagnostics: * Tested the system using the existing, heavily soiled air filter. ​Results: The furnace experienced a "High Limit" trip (overheating) after approximately 4.5 minutes. Subsequent testing mirrored the client’s reported symptoms, with the unit short-cycling (7 minutes ON / 3 minutes OFF). ​Root Cause: Restricted airflow due to the depleted filter caused internal temperatures to exceed safe operating limits, triggering a safety shutdown. ​Recom


Shalik M.

Shalik M. Job Checkin

​Status: Callback Resolved. Issue: Furnace non-operational, Thermostat calling for heat but no ignition. ​Findings & Diagnostics ​Initial Assessment: Upon arrival, the system was unresponsive despite a demand for heat from the thermostat. ​Thermostat Inspection: Verified wiring integrity at the thermostat sub-base. After reseating the unit, the furnace initiated the startup sequence. ​Ignition Failure: The hot surface ignitor glowed as intended, however, the gas valve failed to open, resulting in a lockout. ​Fault Isolation: Diagnosed a loose connection at the gas valve. By securing and manipulating the wiring harness, the gas valve successfully opened. ​Testing: Verified that the gas valve received steady, correct voltage. Manometer testing confirmed stable gas pressures with no significant fluctuations during operation. ​Resolution: ​The system was cycled multiple times to ensure reliability. The furnace operated correctly in both Stage 1 and Stage 2 heating modes without furt


Trevor S.

Trevor S. Job Checkin

Furnace replacement


Joe P.

Joe P. Job Checkin

Navien Combi Bolier NCB 190/080H


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Replaced homeowner provided media filter (16x25x1) and added orientation arrows for proper set up. Furance was not engaging into second stage gas changed the pin P5 from none to 10. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. Andy and Patel Happy Holidays


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Water damage found under the p-trap, tightened the loose gear clamps above and the loose bolts around the draft inducer motor casing. Reccomend replacing media filter (16x25x1) every 3 to 6 months. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. Eva and Ian Happy Holidays!


Andrew S.

Andrew S. Job Checkin

Humidifier Installation


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. and Happy Holidays


Joe P.

Joe P. Job Checkin

Installed furnace


Joe P.

Joe P. Job Checkin

Furnace Installation


Trevor S.

Trevor S. Job Checkin

Furnace maintenance Cleaned and inspected furnace Inspected all electrical equipment Tested gas pressure Cleared out blockage on drain line Tested safeties Performed combustion analysis New 1056 filter Furnace is clean and working well. No problems came up during testing.


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Adjusted the thermostat date from Saturday to Friday: Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. Fireplace Maintenance: Thoroughly cleaned the firebox, removing soot, dust, debris, and any pests. Vacuumed and dusted the ceramic log set, restoring its polished appearance. Inspected wiring to confirm secure connections and overall safety. Cleaned and polished the viewing glass using a specialized fireplace glass cleaner for optimal clarity. Conducted a detailed cleaning of the pilot assembly to ensure reliable performance.


Trevor S.

Trevor S. Job Checkin

Furnace service call Goodman furnace All components are working as they should be. Found a dirty filter. Most likely the cause of low airflow and high limit trip. Furnace never tripped while testing. Recommend filter replacement. Paid with cheque


Wesley P.

Wesley P. Job Checkin

Found blockage in humidifier outlet port. Cleared blockage , tested humidifier. Controlled by ecobee, working normally.dialed water pressure to very slow flow. Client would like to book service for Hrv troubleshoot in the new year. Hrv controller is getting error code. Humidifier operating normally .


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Humidifier is working as should be. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently.