Andrew was kind, answered my many questions and was professional the entire time. I hope he stays with your company a long time and continues to service our city. Much thanks
Great service, have used Evans for last 22years. The technician was friendly and well knowledgeable.
Technician Gary was very knowledgable, efficient, and professional. H
Excellent service very clean, work and thorough. He hast to be one of the best in the business of company man.
Andrew was professional and efficient, I’m very please with his service.
Response from Evans Heating & Cooling:
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
Gary was very efficient and friendly. A pleasure to deal with.
Very professional courteous and skilled Technician. The best I have met in the business. I would recommend him hastily. 20/10
We always call for our heating/cooling maintenance needs! Very professional & knowledgeable, takes time to explain to us
Furnace repair / maintenance. Furnace dual pressure switch was defective. Installed new switch . Performed maintenance on furnace and tested operation . Furnace is operating very well and in good condition. Small amount of Calcium build up under inducer motor but no leak at the time of testing . Possible leak from couple above inducer motor which had been fixed at an earlier time . Fireplace maintenance. Painted back surround of fireplace , cleaned and tested unit . Verified log set when in the right place as per manual . Blower motor bears are starting to wear out and cause a loud rattle noise when fan is turned to full speed .
Furnace maintenance and inspection. Furnace did not appear to have maintenance done for a few years at least. Pilot light was lighting no problem but furnace would not stop sparking for 1-2 minutes on start up every time. Pilot assembly appears to be failing. Board is acting erratic on start up and shut down of furnace, causing blower to cycle on and off multiple times in a row. These parts are showing signs of their age and could fail in the near future. Furnace is operating safely at this time despite the concerns. Highly recommend replacing the furnace opposed to doing any significant repairs in the furnace due to age (33 years old) Water tank is also 20 years old, attaching quote for replacement tank as it is at the end of its life span, chimney also has no liner and would need one if the furnace was replaced and the water heater was not.
Batteries in thermostat were dead, replaced batteries and tested operation of furnace and thermostat. All working well. (Discounted rate on service call as per Amy)
Lennox fireplace maintenance and inspection Fireplace is working well and in good condition.
Furnace maintenance and inspection. Furnace was overheating upon arrival, blower wheel was caked in dust causing poor airflow. Pulled and cleaned blower wheel, recommend filter gets changed in a day or two as furnace will pull lots of dust from the return ducts now that airflow has increased. Inducer motor is leaking condensation from plastic housing causing rust to form below it in the furnace cabinet. Highly recommend replacing this motor if trying to get a few more years out of the furnace.
Sound coming from furnace door not not secured properly , issue was resolved.
2x fireplace and furnace inspection and maintenance. All equipment is working well at this time, no problems found with any inspected equipment.
Installed electric hot water tank and fixed ductwork
14 year old carrier furnace repair / maintenance. Furnace is operating very well , thermostat was not making proper connection to the base on the wall . T stat working properly after remounting to the wall . Performed maintenance on furnace and found humidistat is defective. Bypassed humidistat to test solenoid, and found the humidifier is draining water behind its self . New humidistat and service must be done on humidifier or unit needs to be replaced before use .
Keeprite furnace repair , t stat was replaced with a Honeywell but the common converter was not removed . Furnace fuse had blown . I removed the common converter , tested operation of furnace . Found that the flame sensor had a very low reading 0.5 - 0.1 ua , cleaned sensor and tested again at 3.3 ua . Humidifier solenoid is also defective . Humidistat functioning and receiving water pressure , solenoid not opening .
Gibson furnace repair , defective hot surface igniter . Installed new aftermarket hsi , tested operation of furnace .