Steve and Trevor did a wonderful job installing my new fireplace. I love it!! Great service!!
Response from Evans Heating & Cooling:
We are so grateful for your 5-star review.
Customer complaint: Pilot light keeps going out and a banging noise from the fireplace. Tested fireplace and thermopile—found low millivolt reading. Advised customer that the thermopile needed replacement and proceeded with the replacement. After replacement, the fireplace was still shutting off after about one minute. Inspected flames and found the burner tray was shooting flames from the bottom. Removed the burner tray, cleaned out all carbon buildup, and reinstalled components. Tested the fireplace again—now operating normally with no flames coming from the bottom of the burner tray. Ran the fireplace for 15 minutes continuously with no issues. Possible cause of earlier shutdown: A spill switch or over-temperature sensor detecting unsafe conditions due to flames burning underneath the burner tray. Fireplace is now operating normally and within gas codes and manufacturer recommendations. Advised customer to have Evans perform a deep cleaning on the fireplace once a year due to carbon
Carrier furnace repair. Upon arrival system was cycling on pressure switch error. After performing diagnostics found condensate trap was clogged and heat exchanger was completely full of water. Drained excessive amounts of water, cleaned condensate trap and ensured rest of furnace drain was clear of blockages. Performed CO test, within range. Whie there are no signs currently of any damage to the heat exchanger, it is very likely all that water has taken some life expectancy off the heat exchanger Furnace was working consistently when leaving home, had run steadily since fixing clogged condensate trap. Customer noted loud metal banging sounds in ductwork when home is around 19-20 deg C, showed me video, sounds like a piece of metal hitting another piece. Inspected ductwork for dampers , found none. Advised customer to monitor situation and let us know if it returns Replaced leaking union for fireplace. Iron shaving was preventing old union from making proper seal
Furnace Maintenance: Flushed the condensate line to ensure proper drainage. Inspected pressure switch tubing for functionality. Cleaned and polished the flame sensor to optimize performance. Conducted diagnostic testing, confirming the system is operating efficiently. Furnace is operating well. Happy New Year,
Furnace and Air Conditioner Installation
Weil McLain boiler maintenance and inspection. Boiler is in decent shape considering the age, found no problems or concerns during visit. Everything is operating as intended at this time. Performed CO test and certified boiler for 12 months.
No heat - Upon arrival - unit going through the sequence of operation but gas valve not allowing gas to flow. Verified ventor motor 1.84w.c Pressure switch -1.13 Circuit board is sending 27.63 v to the gas valve. Gas valve no opening up. Replaced gas valve, set gas pressures, tested for leaks. No leaks. Tested system Fully operational See photos
Ductless mini split installation service call. Customer needed a Daikin Cirra Ductless installed. Performed air conditioning installation and checked for proper operation.
Fireplace maintenance and inspection
Ac service call. Replaced capacitor 30-5uf.
Cosmo SLR32 gas fireplace (showroom model)