4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
9053544424

Local Reviews
for crystal beach, on

Rated 5.0 out of 5 stars based on 6 customer reviews

Amazing Service

Very professional and fair pricing!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!!

Steve and Trevor did a wonderful job installing my new fireplace. I love it!! Great service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job!!

Well done!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great!


Response from Evans Heating & Cooling:

We are so grateful for your 5-star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

Pleased with his professionalism and excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for crystal beach, on

Wesley P.

Wesley P. Job Checkin

Customer complaint: Pilot light keeps going out and a banging noise from the fireplace. Tested fireplace and thermopile—found low millivolt reading. Advised customer that the thermopile needed replacement and proceeded with the replacement. After replacement, the fireplace was still shutting off after about one minute. Inspected flames and found the burner tray was shooting flames from the bottom. Removed the burner tray, cleaned out all carbon buildup, and reinstalled components. Tested the fireplace again—now operating normally with no flames coming from the bottom of the burner tray. Ran the fireplace for 15 minutes continuously with no issues. Possible cause of earlier shutdown: A spill switch or over-temperature sensor detecting unsafe conditions due to flames burning underneath the burner tray. Fireplace is now operating normally and within gas codes and manufacturer recommendations. Advised customer to have Evans perform a deep cleaning on the fireplace once a year due to carbon


Andrew S.

Andrew S. Job Checkin

Carrier furnace repair. Upon arrival system was cycling on pressure switch error. After performing diagnostics found condensate trap was clogged and heat exchanger was completely full of water. Drained excessive amounts of water, cleaned condensate trap and ensured rest of furnace drain was clear of blockages. Performed CO test, within range. Whie there are no signs currently of any damage to the heat exchanger, it is very likely all that water has taken some life expectancy off the heat exchanger Furnace was working consistently when leaving home, had run steadily since fixing clogged condensate trap. Customer noted loud metal banging sounds in ductwork when home is around 19-20 deg C, showed me video, sounds like a piece of metal hitting another piece. Inspected ductwork for dampers , found none. Advised customer to monitor situation and let us know if it returns Replaced leaking union for fireplace. Iron shaving was preventing old union from making proper seal


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Flushed the condensate line to ensure proper drainage. Inspected pressure switch tubing for functionality. Cleaned and polished the flame sensor to optimize performance. Conducted diagnostic testing, confirming the system is operating efficiently. Furnace is operating well. Happy New Year,


Gary T.

Gary T. Job Checkin

Furnace Maintenance and Inspection


Steve E.

Steve E. Job Checkin

Gas Fireplace installation


Steve E.

Steve E. Job Checkin

Furnace and Air Conditioner Installation


Andrew S.

Andrew S. Job Checkin

Weil McLain boiler maintenance and inspection. Boiler is in decent shape considering the age, found no problems or concerns during visit. Everything is operating as intended at this time. Performed CO test and certified boiler for 12 months.


Chris V.

Chris V. Job Checkin

No heat - Upon arrival - unit going through the sequence of operation but gas valve not allowing gas to flow. Verified ventor motor 1.84w.c Pressure switch -1.13 Circuit board is sending 27.63 v to the gas valve. Gas valve no opening up. Replaced gas valve, set gas pressures, tested for leaks. No leaks. Tested system Fully operational See photos


Joe P.

Joe P. Job Checkin

Air Conditioner Installation


Joe P.

Joe P. Job Checkin

Ductless mini split installation service call. Customer needed a Daikin Cirra Ductless installed. Performed air conditioning installation and checked for proper operation.


Gary T.

Gary T. Job Checkin

Fireplace maintenance and inspection


Joe P.

Joe P. Job Checkin

Daikin Ductless Heat Pump


Cameron T.

Cameron T. Job Checkin

Fireplace and Ac maintenance.


Gary T.

Gary T. Job Checkin

Ac service call. Replaced capacitor 30-5uf.


Jack M.

Jack M. Job Checkin

Cosmo SLR32 gas fireplace (showroom model)