4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Job Locations
for st. catharines, on


Map of St. Catharines ON
Wesley P.

Wesley P.


Job Checkin

Inspection Summary – Gas Bonding Deficiency Identified During inspection, we identified a bonding infraction related to the gas line: the gas-tite piping is not properly bonded. This has resulted in a red tag from Enbridge, although the client still has gas service at this time. The red tag expires on June 25. We will provide a quote to correct the bonding issue by installing a bond wire from one end of the gas-tight line to the other, and then properly terminating it at the bonding bar in the electrical panel. Once this work is complete, we will be able to clear the red tag. No additional service charge will apply when we return to perform this work—the quoted price will remain the same as if it had been done today. Additional Recommendations: Perform a boiler maintenance on the Navien system, including a full inspection of both the space heating and domestic hot water components. Complete a tankless flush to maintain efficiency and extend the life of the unit. Schedule air condit