Seth M.

Seth M.


Job Checkin

For this job, the customer thought the wire was cut for the AC system. So I proceeded to check the wiring and found them in good shape. I did not see any cut wires so I turn on the AC and found the compressor working, but the fan motor would not come on. I checked the capacitor readings and found them good. I also checked the amperage coming from the condenser fan motor and found I got amperage going to it and out. But the motor would not come on. My recommendation is to replace the fan motor or install a new AC system because this system is 20+ yrs old and the type of Freon is no longer available. I did try to call both customer but they were not available, but the customer‘s mother was there and she had paid the bill. There is no issue with the thermostat wire, but I did find the fan motor is burnt out.