Commercial Water Filtration System Installation. When a client called us to install a new water filtration system, I arrived, ready to take on the task. I undertook the installation of an advanced water filtration system. The upgrade met the client's stringent requirements and ensured crystal-clear water, aligning with the expectations of establishments.


Ashley B.

Ashley B. Job Checkin

Commercial Booster Heater Installation: In an effort to improve water heating efficiency, we seamlessly installed a booster heater into the existing kitchen infrastructure. This upgrade significantly enhanced overall performance and hot water delivery.


Daniel  D.

Daniel D. Job Checkin

The juice and soda beverage dispenser does not have enough CO2 pressure and the soda is coming out flat. Troubleshoot the CO2 supply and adjust to the correct psi according to the manufacturer's limit.


Mark B.

Mark B. Job Checkin

Arrived at location on 8/4/21 - Replaced switch for steamtable. Plugged in and tested, all ok.


Service C.

Service C. Job Checkin

examined HOB Dishwasher unit, found wash tank contactor kicks off at 178 when sitting started using and temp slowly drops to 140. turned up booster temp setting to 194. now rinse temps are 186 to 188 this helped wash temp up to 146 when operating found 1 part of wash element not heating will order and return. 3/17/21 replaced wash element cleaned off temp probe filled tank no leaks heated to 180 customer set point started running trays rinse up to 188 wash never went below 162 after 12 trays element drawing 45 amps per leg all 3 all okay.


Service C.

Service C. Job Checkin

Replaced CMA Dishwasher pump and hoses, cut back incoming water line and attached, filled with water and ran for several minutes - no leaks during repair. We broke cap tube for wash temp and wash hi limit - will replace at no charge.


Service C.

Service C. Job Checkin

9/14/20 Got Reach-In Cooler model and s# model Dl3r s#135A1730 continental gasket left door 21.5by 60.5 and id'd gaskets. Will order and return. 9/21/2020 Replaced right and left door gaskets.


Service C.

Service C. Job Checkin

Examined Convection Oven, unit found glass broken on bottom oven left door glass cannot be replaced, customer needs new door assembly - spoke to Jamie, will order new door. 6/16/2020 Removed and replaced left door and bushings, adjusted heated and tested all okay


Service C.

Service C. Job Checkin

Examined Convection Oven unit, found igniter weak, replaced, also found flame sensor out of alignment, cleaned and adjusted and tested, unit working at this time.


Service C.

Service C. Job Checkin

Examined Ice Machine unit and found ice level near bottom of bin. Found no error codes on board. Watched freeze cycle. Ice sheet okay and harvest okay. Every now and then water pump stops. Will order new pump locally. Called United. They will have one on Monday. 12/30/19 Returned and removed faulty water pump. Installed a new water pump. Checked 3 cycles.


Service C.

Service C. Job Checkin

Examined Booster Heater unit. traced issue to booster heater not heating. relay board bad. not powering contactors and shows sign of corrosion. will order and return. customer is currently using low temp chemicals. 11/26/19 located breaker which is shared with disposal. removed and replaced temp controller. programmed and tested. ran dishwasher to cycle unit. rinse at 190 on dishwasher. good to go


Service C.

Service C. Job Checkin

examined Convection Oven unit, opened top cover, adjusted switch and bracket and tested, all okay


Service C.

Service C. Job Checkin

Opened Hot Well front panel, had water spill out on me. Found breaker tripped, on off switch okay found set control board. 1=deltbp00131= board Also bring 3" poly tube to raise board on posts. 1/25/19 r&r control board, started to heat, put panel back on, would not turn on. Found bad connection to switch. Allowed unit to heat and cycle.


Service C.

Service C. Job Checkin

Performed complete certification. Cleaned, adjusted and calibrated as needed, all okay.


Service C.

Service C. Job Checkin

Examined unit. Found 2 bad relays (bottom front and bottom back). Replaced and tested. Unit up and running.