1833 North Cameron Street
Harrisburg, PA 17103
(800) 932-0503

Local Reviews
for state college, pa


Job Locations
for state college, pa

Mark B.

Mark B. Job Checkin

Arrived at location on 9/8/21 - Found unit switched off at front display. This controller sometimes is sensitive to power outages and power fluctuations and will shut itself down. Started and cycled system two times checked temps inside cabinet and on controller all ok. Front display/controller is busted up will order new part. Returned to location on 10/6/21 - Replaced fault control. Set temp and ran defrost. Working normally at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/23/21 - Found cooler at 48 degrees. Checked operations and found cooler needs a new thermostat and probes. Returned on 7/29/21 - Installed new control and when I tried to install probes found evap coil a solid block of ice and interfering with the removal of the drawer racks. Will let unit off overnight and return in the morning to install probes. Returned on 7/30/21 - Unit on and evap a block of ice. Told manager to leave off overnight Sunday and we will return Monday morning. Returned on 8/2/21 - Installed new probes in evap. Unit cooling but showing E13 error. Spoke with Delfield and issue communication error. Will need to replace display and communication cable. Will order and return. Returned on 8/6/21 - replaced display and cable on cooler working ok.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/13/21 - found unit off. Ran. Found unit got to setpoint 300° and cycled off. Let cool. Found did not turn on until 200°. Heated again cycled off at 275° and on at 210°. Swing too large and calibration off. Will obtain control and probe.


Mark B.

Mark B. Job Checkin

Found wash pipe leaking at tank connection. Removed and sealed. Will order new gaskets. Customer will wait for 3 hrs for sealant to set up before filling machine. Removed discharge line from pump and cleaned silicone from gasket surfaces. Installed line with new gaskets. Filled tank and ran. Found no leaks. Unit ok at this time.


Service C.

Service C. Job Checkin

Removed side panels and started Steamer unit. While filling checked for leaks and didn't see any. While heating checked voltages and amp draws and ok. Once hot started leaking a lot, shut down unit. Leak coming from left rear. Removed back panel and found steam generator cracked on corner weld. Generator will need replaced. Customer needs quote for repair sent to dcarson@harmonystatecollege.com generator part# 6947-1 gasket# 9-3214


Service C.

Service C. Job Checkin

Found IMP Range units idle, tagged and etched all imperial units with all specs according to imperial and code. took pictures and sent to customer and to inspector and got approval from both. all units are now marked with the model number, converted to natural gas, w.c, and NSF tag number. all units now certified and up to code.


Service C.

Service C. Job Checkin

While working on grill heard fryer popping. Popping coming from center vat. Removed combustion blower and ignitors. Found right side ignitor damaged. Pilot tube almost gone. Inspected burners for cracks and found none. Replaced ignitor and started unit. Heard another pop on first ignition. Lowered manifold pressure to 3.1"wc. Let unit heat and heard no more popping. Unit heating normally and ok at this time.


Service C.

Service C. Job Checkin

found Bottom Oven unit off. replaced control. turned on. found no power. inspected. found disconnected wiring at resets and safety switch. tested switch and breaker found okay. reconnected wiring. ran found normal operation. let heat. came to set point 470. found unit cycled normally. customer tested product. found okay.


Service C.

Service C. Job Checkin

Found top combi oven water supply line leaking. Will need to replace supply line. Cleaned up excess water. Will obtain supply line and return. 11/14/19 Removed faulty supply line. Checked water pressure and okay. Installed new water supply hose. Checked for leaks and tested unit. Ran in steam mode and steaming normally. Unit okay at this time.


Service C.

Service C. Job Checkin

Call out - Found Reach-In Cooler unit low on charge, found small leak at flare fitting on receiver. I was able to get 1/2 turn on it and checked again and unit not leaking any longer. I used electronic tester and went over evaporator and condensing unit found no other hits, charged system to 80% receiver level and system dropped in temp, system is working properly now.


Service C.

Service C. Job Checkin

Removed faulty control and installed new control on Walk-In Freezer. Set high and low pressure switches. Tested for leaks found none. Ran and cycled system okay. Insulated line that was rubbing on condenser box housing.


Service C.

Service C. Job Checkin

Customer stated hi limit tripping. Inspected unit and doesn't seem to be over heating. Relay not sticking so hi limit tripping early. Will order hi limit and return. 10/9/19 Removed bottom of unit. Removed faulty hi limit and cover plate. Installed new hi limit and mounted capillary bulb with spacer and mounting plate. Put components back together and tested. Unit heated to temp normally. Okay at this time.


Service C.

Service C. Job Checkin

Customer stated outlet stopped working on Warming Cabinet. Turned off breaker to outlet. Pulled outlet from wall and checked wiring. All wiring secure. Turned on breaker and checked voltage. Found 115v to outlet. Put outlet back in wall and tested. Found 115v out of outlet. Removed plug from power cord. Cut back wiring and hooked up fresh wiring. Tested and unit working normal


Service C.

Service C. Job Checkin

Found Dairy Dispenser unit showing empty on slot A but not, and not dispensing. Spoke with tech support at Silver King and re-calibrated unit. After calibration, unit working normally. After emptying product, found inside very iced up. Removed build up before restocking product. Unit okay at this time.


Service C.

Service C. Job Checkin

When powered on glove steamer unit not heating. Checked for voltage from relay to element and found high limit tripped. Unable to reset hi limit. Jumped out hi limit and unit started to heat. Hooked hi limit back up. Will need to replace hi limit. Will order and return. 08-13-18 Removed faulty limit and installed new limit filled with water and cycled 4 times. Unit is in proper working order at this time.