5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for buford, ga


Map of Buford GA
Jon F.

Jon F.


Job Checkin

Completed 2 system maintenance found both furnaces 20 years old with very dirty blower wheels and brittle ignitors. Upstairs has failing capacitor and downstairs has failing under motor. Furnaces need to be replaced for better efficiency. Neither has water safety and need float switches to protect house and furnace from water damage. Outdoor systems have good pressures and good electrical components. Having Garrett come give quote for new furnaces.