One system heat maintenance in Loganville. Arrived on site, checked filter and cleared barometric port. Checked ignition systems, electrical connections, amp draw and capacitance. Found system without water safty, recommend installing in addition to surge protector to protect electrical systems. Also recommend pulling and cleaning blower motor assembly to keep fan properly balanced. Recommended installing uv system to improve air quality inside house. Unit is operating within manufacture spec at this time