Job Checkin

Work Performed: Performed air conditioner maintenance on a system installed by us in 2017. Findings: Reviewed past service history: in 2023, UV dye was added by Jordan to investigate a suspected refrigerant leak. However, no follow-up leak detection was documented. During today’s visit: Refrigerant levels were steady and unchanged since the 2023 visit No UV dye was found in the drain or on system components No oil staining was visible Checked Schrader cores—no signs of leakage The source of the original issue remains unclear, but the system appears to be holding refrigerant well over the past year. Routine AC Maintenance Completed: Verified refrigerant pressures and temperature split Inspected electrical components (capacitor, contactor, wiring) Flushed the condensate drain Checked the air filter and airflow Cleaned the outdoor coil Verified system operation and thermostat function Additional Notes: Discussed the Comfort Club with the client, including benefits like 15% off repair