Work Performed Inspected fireplace due to client and insurance concerns regarding soot above the termination. Verified installation against manufacturer specifications and current gas codes. Inspected operation and condition of unit. Results Fireplace installation is to code (termination is 12 inches to unvented soffit, acceptable per manufacturer and gas code). Soot observed above termination is a normal byproduct of operation and can be wiped/cleaned off. Fireplace is operating normally and is in very good condition; client keeps unit well maintained. Blower wheel is seized and requires replacement. Optional: A heat shield can be added on the exhaust to help reduce buildup on the wall. Recommendations Provide estimate for blower wheel replacement. Provide optional estimate for exhaust heat shield.(may not be available)