Work Performed Responded to no cooling call; found outdoor AC unit not running due to failed capacitor. Replaced capacitor and restored power to unit. Performed full air conditioner maintenance as part of new Comfort Club enrollment, including cleaning the outdoor unit. Checked refrigerant levels and temperature drop — both within normal range. Tightened bolts on outdoor unit and applied WD-40 to reduce vibration noise. Results AC system is now operating normally with good cooling performance. Refrigerant levels and temperature drop confirmed normal. Outdoor unit cleaned; noise reduced, though outdoor fan motor still shows slightly higher vibration than typical. Recommendations Monitor vibration from outdoor fan motor; may indicate early wear. Continue regular maintenance through Comfort Club to maximize lifespan. System is from 2009 and in decent shape; no immediate replacement needed.