4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Job Locations
for st. catharines, on


Map of St. Catharines ON
Wesley P.

Wesley P.


Job Checkin

Service Type: Furnace Maintenance Equipment: 2004 Lennox High-Efficiency Furnace Inspection & Findings: - Completed furnace maintenance. - Inducer motor remains loud and vibrating; condition noted during last year’s maintenance as well. - Older ABS venting inspected and found to be in fair condition; advised regular inspection for cracks or leaks. - Humidifier operating normally. - Burners showing rust and age-related deterioration. - Ignitor resistance reading measured low at approximately 17 ohms, indicating wear; ignitor may not last. - OEM ignitor required for this unit. - Combustion analysis performed and results are within acceptable range. Blower wheel inspected and found coated in dust and debris. May be hindering performance. Small water leak from exhaust drain diverter left hand side(exhaust is right) Recommendations: - Recommend replacing inducer motor due to noise and vibration. - Recommend replacing burners due to rusting and risk of burner port restriction and shutdow