4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Job Locations
for welland, on


Map of Welland ON
Shalik M.

Shalik M.


Job Checkin

Furnace Maintenance: Adjusted hi-fire to 3.5"wc as for the manufacturer requirements. Replaced the media filter with homeowner provided media filter for optimal airflow. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently. Fireplace Maintenance: Thoroughly cleaned the firebox, removing soot, dust, debris, and any pests. Vacuumed and dusted the ceramic log set, restoring its polished appearance. Inspected wiring to confirm secure connections and overall safety. Cleaned and polished the viewing glass using a specialized fireplace glass cleaner for optimal clarity. Conducted a detailed cleaning of the pilot assembly to ensure reliable performance. The pilot still refused to stay lit, our pilot assembly needs to be replaced for proper operation. Reached out to