Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Performed a heating maintenance on a 2020 American standard gas furnace, Filters located throughout house ceiling, fua located in attic, attic access outside house, upon arrival pvc pipe was cracked proceeded to notify HO and gave me the ok to replace the male fitting and 2ft of pvc also, changed filter, flushed condensation line through jones valve, on fau followed sequence of operation, checked for amperage and voltage, checked for blower speed, check for any loose connections, check for temperature rise, everything within range also cleared dust accumulated inside electrical component. System is working within specification in heating at the time of maintenance.