Christopher was very professional and explained everything where I understood, thank you Christopher
Alex was friendly, informative and helpful. Very professional
Technician arrived at designated time. Very friendly and efficient.
Miguel was professional and thorough with my heating unit. He explained the process and readily answered my questions.
I think you need to hire somebody that knows how to work on the older Coleman furnaces in the homes
Response from Hydes Air Conditioning:
Hi Buddy thank you for your feedback. We always encourage our employees to ask for an assist if they don't have as much experience on a particular type of equipment. In this case, Amador didn't feel prepared for the issues he encountered and we are so glad he called upon a teammate to help him with the repair. I apologize if this was inconvenient but rest assured you got an expert and there was no additional charge. Have a wonderful day!
Great, fast service. Hydes does what they say they will do. Technician James was excellent.
Left message for Donna (voicemail)
Executed a cooling maintenance on a split system (technician notes). Replaced filters and washed condenser coil. Installed compressor saver kit – client paid via C.C. running and starting amperage measured within manufacture specifications. Refrigerant circuit diagnostic – good. System is cooling the home at the time of maintenance.
Executed a cooling maintenance on a split system. Replaced filters and wash down condenser coil. Refrigerant circuit diagnostic – good. Running and starting amperage measured within manufacturer specifications. Capacitor – good. Thermostat is janky. Recommend replacing – estimate sent via email. System is cooling the home at the time of maintenance.
Executed a cooling maintenance on a split system (technician notes). Replaced filter and wash down condenser coil. No current alerts or notifications on CDA. Refrigerant circuit diagnostic – good. Electrical components and motors function according to manufacture specifications. System is cooling the home at the time of maintenance.
Performed annual maintenance in cooling on a American standard split, followed sequence of operation Changed filters checked amps voltage capacitor compressor savor pressures working at range rinsed condenser down unit is working to manufacture specification in cooling
Performed annual maintenance in cooling on a American standard package unit, followed Sequence of operation Changed filter checked amps voltage capacitor compressor savor temperature split working at range cleared condensation line rinsed coil down unit is working to manufacture specification in cooling, we will be installing mini split for office to schedule
Upon arrival found condenser running but blower was not. Capacitor checked out in range. Motor was overheated and making a buzzing noise when attempting to start. Informed, recommended and replaced blower motor. Tested and cycled system. System is cooling properly at this time of service.
AC System Repairs: Addressed water leaks from an AC unit by replacing a cracked drain pan and ensuring proper drainage.
Refrigerant Leak Detection and Recharge: Located a slow refrigerant leak during system diagnostics. Sealed the leak and refilled refrigerant to restore peak cooling.
HVAC Drain Line Cleaning: Responded to a report of water pooling near an HVAC unit. Found a blocked condensate drain line, cleared it, and restored proper drainage to prevent future leaks.
Performed annual cooling maintenance on a 2019 American Standard Silver 4ton unit. Coleman FAU located in laundry room. Replaced 2) 16x20 filters. Followed sequence of operations and checked voltage, amperage, capacitor, hard start kit, temperature split, Freon levels, and rinsed condenser coils. Everything checked out operational. Ecobee thermostat checked out operational. System is working properly in cooling at this time of service.
Dropped off requested filter
Perform annual heating maintenance on 2019 train split heat pump air handler located in outside closet. I will need to return to change 14 x 20 filter. Checked amps, volts, capacitor and cleaned electrical compartment. Recommended and installed new 70/7.5 micro ferric capacitor. Check refrigerator levels, superheat, subcool, and temperature split. Cleared line and washed condensing coil. Found all other electrical components and refrigerant levels to be within manufactured specifications. System is operating appropriately.
Performed cooling maintenance on 2016 American Standard Platinum split systems. Cleared condensation drain. Changed 20x24 upper wall filter grille. Checked 1050 thermostat, no alerts, history, and reminders. Cleaned out drive compartment. Cleaned condenser coil. Checked amps, volts, refrigerant charge, and temperature split. Surge protector light on. System is cooling properly at time of service.
Performed annual maintenance in cooling on a 2017 reem split followed sequence of operation Changed filter checked amps voltage capacitor pressures working at range cleared condensation line rinsed condenser down unit is working to manufacture specification in cooling at this time of visit