Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Homeowner has (2) gas furnaces , one in kitchen attic access, the other in garage access, garage unit for guest rooms side of home, kitchen area furnace for living room partially and master bedroom side of home. Guest rooms and dining room with garage furnace were too hot to them. Was getting. 130°+ with high velocity. Adjusted gas pressures lower end of manifold pressure and found speed two in medium hi, per specs I switched to low. Getting 40° heat rise, no limits going off. For master bedroom issue, they were getting cold at night with furnace running. I confirmed it is running in heat, and not in cool. Only one supply but they said no issue cooling in summer. Supply temp was about. 107° and speed tap on low. I switched speed tap to medium hi and got much better heating, now they could feel it near their bed. Homeowner stated it felt better as well. Adjusted a little to keep it all within manufacture specs. Both systems are now heating properly and within manufacture specs/design b