Maintenance for heat on a 2013 American standard gas package unit. Condensation line cleared filter changed. System cycling and came on in sequence. Check inducer motor, gas valve, and average draw. Check temperature split system is working per manufacture specifications. Home is heating properly. Customer ask if i could check for cooling. Switch to cooling check tempature split and compressor amps. noticed capacitor was reading low microfarads, check compressor amps and noticed it was over amping. Notified customer of the findings. Recommended new capacitor and compressor savor kit. Customer agreed, installed new capacitor and hard start kit. Tested compressor amps and showed customer the results. System is working per manufacturer specifications. Home is cooling properly.