Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Performed annual cooling maintenance on two (2) 2015 Payne split systems. Replaced one 14x25 air filter. Verified 20x25 filter had already been replaced by homeowner. Followed full sequence of operations for both systems. Checked refrigerant (Freon) levels. Measured temperature split. Inspected electrical components. Cleared condensate drain lines to ensure proper drainage. System S#2727: Refrigerant level found slightly low. Recommend adding approximately 1–2 lbs of refrigerant. Capacitor rated at 70/7.5 µF tested at 63 µF. Capacitor is below acceptable range and recommended for replacement. An estimate was provided to the homeowner for refrigerant adjustment and capacitor replacement. Homeowner will discuss with spouse before proceeding. Both systems were operational and functioning properly at time of service.