Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Arrived to diagnose a potential issue with the main breaker. During testing, I confirmed that the busbar was only receiving power on one leg of the main breaker. I observed discoloration and signs of deterioration on the busbar. I informed the homeowner that if we proceed with replacing the main breaker and any damage to the busbar is found, a complete panel upgrade may be necessary. Additionally, if the busbar behind the main is not fully damaged and we install a new main breaker, I cannot guarantee the long-term reliability of the panel. I strongly recommended upgrading the panel to prevent future issues.