42949 Madio St.
Indio, CA 92201
(760) 360-2202

Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.


Job Locations
for palm springs, ca


Map of Palm Springs CA
Thor J.

Thor J.


Job Checkin

Homeowner has 3 ecobee thermostats for home and only the family room thermostat seems to be reading temperatures inaccurately, when they heat it to 73° it will jump to 77° and in cooling will drop down to. 68° when setpoint is in 70°s. Thermostat seems to overshoot. System turns on and off properly but noticed hot draft right into thermostat and found supply register pointing to thermostat causing sensor inside to read temperatures well out of range. Adjusted supply register to point away from thermostat. Recommended using Ecobee sensors instead of moving thermostat. Homeowner signed estimate. Will get with office to schedule me to return to install and setup/test sensors. They need it done within 2 weeks due to family coming down. Booked upcoming summer maintenance for Thursday, April 2nd from 12:30 PM - 3PM.