340 Quinnipiac Street / Building 33
Wallingford, CT 06942
203-815-6851

Job Locations
for wallingford, ct


Map of Wallingford CT
Andrew H.

Andrew H.


Job Checkin

Performed 1 split system ac pm and 1 ductless ac pm. Washed condenser coil Checked all electrical connections and safeties Blew out drain lines and poured water to ensure proper draining Tested all heads in high heat and cool Checked volts and amps Visually inspected evap coils, blower compartments and filters All heads were putting out 120-123 degree air in high heat mode and were putting out 39-43 degree air in high cool mode. Units are operating properly While testing the drain lines we found the condensate pump inside the knee wall was working intermittently and was leaking some water. Took a picture of the pump to order a replacement Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps While perform