confirmed with Anthony for 8am Sprinkler Inspection
confirmed with Greg Fire Hydrant and Sprinkler Inspection
confirmed with Stacy for 1:30, or earlier Sprinkler Inspection
Annual Sprinkler Inspection Semi-Annual Sprinkler System Inspection Sprinkler Inspection
confirmed with Alan Brown Sprinkler and Antifreeze Loop Inspection Annual Sprinkler Inspection- MAIN BUILDING (1) WET (1) DRY Annual Sprinkler Inspection- COLD STORAGE BUILDING (1) WET Annual Anti-Freeze Loop- MAIN BUILDING
DO FIRE PUMP ANNUAL INSPECTION WITH THIS Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. Liberty Fire Solutions strongly recommends that your sprinkler system is repaired so that it will become compliant. The fire sprinkler system as-is will not work properly due to the above referenced deficiencies and may not extinguish, suppress or control a fire. This is a safety hazard and may contribute to damage or injury to your property and individuals in the event of a fire. Please contact me as soon as possible to review the attached proposal and s
Fire Pump Inspection Annual Fire Pump Inspection
Fire Hydrant and Fire Pump Inspection Annual Fire Hydrant Inspection Annual Fire Pump Inspection
Lightning struck- fire pump continuously running Call Mark when onsite 717-644-5652, he has pump shut off currently Fire Pump Service Call
confirmed with Melanie for 7am. Deficiency for Ansul Autofry 40oz: Ansul auto fry system is due for cylinder hydro test ( every 5 years ) System is due for cable replacement also Cylinder hydro test Ansul auto fry cable replacement
Semi-Annual Clean Agent Suppression Inspection Equip Desc: FIKE ECARO-25 -- 3RD FLOOR - ELECTRICAL ROOM
Semi-Annual Kitchen Suppression Inspection -ANSUL Semi-Annual Clean Agent Suppression Inspection Equip Desc: CHEMETRON AA309769 -- COMPUTER SERVER RM Deficiency for Range Guard Rg2.5g 2.5 gallon Left wall: Convection oven does not shutdown when system trips Electrician needed for convection oven to shutdown when system is activated