Annual Extinguisher Inspection Equip Desc: (2) ABC(s)
See Alan Roy stating multiple alarms as previously reported Sprinkler Service Call
confirmed with Lois Sprinkler Inspection
Deficiency for ANSUL R-102 3G KITCHEN: Alarm bell is present but not working up air does not shut down when system is tripped Electric outlet microwave is plugged into does not shut down Patch panels and holes in hood and plenum need welded Fan switch needs relocated(currently under the hood) Electric wiring in plenum needs removed and hole sealed Duct needs welded to plenum Spice shelf is blocking 1F nozzle on left side of range Electrician needed Welder needed Remove spice shelf or repipe nozzle Inoperable Deficiency for ANSUL R-102 3G KITCHEN: Alarm bell is present but not working Make up air does not shut down when system is tripped System will be overflowed due to bigger fryers Patch panels and holes in hood and plenum need welded Electric wiring in plenum needs removed and hole sealed Duct needs welded to plenum Drops above fryers need aimed and lowered Drop above griddles needs moved and aimed properly Detection bracket for right fryer needs moved to right Gas does no
ok'd by water authority Fire Hydrant Inspection
confirmed for 8am Fire Pump, Backflow, and Sprinkler Inspection
confirmed with Randi Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 3 year pressure test of the dry system per NFPA 25. NFPA 25 REQUIREMENTS FOR YEAR TESTING: NFPA 3.4.3.2.6 With the system at normal system pressure, shut off the air source (compressor) for 4 hours. If the low air pressure alarm goes off within this period, the air leaks shall be addressed. Notice of Three Year Dry Sprinkler System Pressure Test Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your
One bus I could not get he left before my arrival Randy’s bus #993 They will get ahold of us when we can stop and get it CONFIRMED WITH RANDI FOR 7AM -DO BUS EXTS FIRST 1- 6YR Portable Extinguishers Inspection
confirmed with Allan Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 3 year pressure test of the dry system per NFPA 25. NFPA 25 REQUIREMENTS FOR YEAR TESTING: NFPA 3.4.3.2.6 With the system at normal system pressure, shut off the air source (compressor) for 4 hours. If the low air pressure alarm goes off within this period, the air leaks shall be addressed. Notice of Three Year Dry Sprinkler System Pressure Test Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your
confirmed with Laura for afternoon Industrial/Dry Chemical Suppression Inspection