Local Reviews
for bellefonte, pa

Rated 5.0 out of 5 stars based on 1 customer reviews

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bellefonte, pa

Jason  M.

Jason M. Job Checkin

Special Hazards Repair


Jason  M.

Jason M. Job Checkin

Special Hazards Inspection


Jason  M.

Jason M. Job Checkin

Portable Extinguishers Inspection


Joshua M.

Joshua M. Job Checkin

Portable Extinguishers Inspection


Jason  M.

Jason M. Job Checkin

Sprinkler Repair


Bill  B.

Bill B. Job Checkin

confirmed with Jonathan -basement door is unlocked Backflow Inspection


Bill  B.

Bill B. Job Checkin

Andy 814-404-8762 Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 3 year pressure test of the dry system per NFPA 25. NFPA 25 REQUIREMENTS FOR  YEAR TESTING: NFPA 3.4.3.2.6 With the system at normal system pressure, shut off the air source (compressor) for 4 hours. If the low air pressure alarm goes off within this period, the air leaks shall be addressed. Notice of Three Year Dry Sprinkler System Pressure Test Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your est


Bill  B.

Bill B. Job Checkin

Portable Extinguishers Inspection Annual Fire Extinguisher Inspection (12) ABC


Bill  B.

Bill B. Job Checkin

confirmed with Jonathan for 8:30/9am Sprinkler and Backflow Inspection


Bill  B.

Bill B. Job Checkin

Sprinkler Inspection Annual Sprinkler System Inspection 1- WET 1- WATER GAUGE Quarterly Sprinkler System Inspection


Bill  B.

Bill B. Job Checkin

call Cory when are arrive. 814-571-1381 Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Special Hazards Inspection Deficiency: Small Chemetron FM 200 tank lost pressure No heat in room with tanks ( possibly lost charge and leaked due to being cold over last winter ) Inoperable Deficiency: Small Chemetron FM 200 tank lost pressure No heat in room with tanks ( possibly lost charge and leaked due to being cold over winter months) Recharge cylinder or replace cylinder


Joshua M.

Joshua M. Job Checkin

Portable Extinguishers Inspection.


Bill  B.

Bill B. Job Checkin

Sprinkler Inspection confirmed with Cory Moore


Bill  B.

Bill B. Job Checkin

confirmed with Cory Sprinkler Inspection