Annual Sprinkler System Inspection (4) WET (1) DRY (1) Pre-action (newly installed in 2025) Deficiency: Dry system is due for 3 year pressure test 3 year pressure test
Semi-Annual Suppression System (data room) Deficiency: Need warning signs inside of server room and outside of room 2 Agent warning signs
Annual Sprinkler System Inspection Deficiency: System is due for 5 year internal inspection and gauge replacement System is due for 5 year FDC hydro test 5 year internal inspection FDC hydro test 2 water gauges Storz connection ( cannot access check valve is ceiling above back office)
CHEMETRON 10480994 -- OFFICE BLDG - SERVER ROOM See why alarm is going off Deficiency: FM 200 system in server room does not have its own HVAC system All ducts in server room are tied into the building per Scott Damper needed for return HVAC needs to shutdown Electrician needed Deficiency: FM 200 system in server room does not have its own HVAC system All ducts in server room are tied into the building per Scott Damper needed for return or HVAC needs to shut down Electrician needed
Semi-Annual Kitchen Suppression Inspection Equip Desc: PYRO-CHEM PCL-300 -- KITCHEN
Quarterly Sprinkler System Inspection
Semi-Annual Kitchen Suppression Inspection Equip Desc: RANGE GUARD RG6G -- KITCHEN
Annual Extinguisher Inspection (2) ABC 1(K CLASSS) Semi-Annual Kitchen Suppression Inspection Inoperable Deficiency for Ansul R-102 6 gallon Kitchen: Detection line failed due to grease buildup in conduit Duct has excessive grease buildup 4 Ansul detector kits 15' cable Duct needs cleaned
Sprinkler Inspection Deficiency: 5 year internal inspection and gauge replacement due 5 year FDC hydro test due 3 year pressure test due Upright Heads are due to be sent out for UL testing ( 50 years) 1974 5 year internal inspection 5 year FDC ( check valve is in basement) Tem 6 threads same as Pittsburgh 6 3 year pressure test 3 air gauges Pull 8 upright heads basement and 3rd Floor ( 212 degree 4.0 K factor)
confirmed with Kevin -if Kevin isn't there, ask for Matt Strait Industrial/Dry Chemical Suppression Inspection