bill was very knowledgeable and well prepared and extremely good at his work
verry knowledgeable about the fire suppression industry and easy to talk to
Very nice people, and a great company. The technician, Jason Musselman, was very professional, knowledgeable, and, and courteous. I would highly recommend. Appreciate everything!
Called on a Friday and they were here on Monday, quick service and helpful with answering questions.
Bill always does a great job! On time, friendly, and efficient!
Jason always does a great job and explained the system reset to me.
I would gladly, without hesitation refer Liberty Fire Solutions to anyone who needs knowledgeable help. From Paisley who I spoke with in the beginning and Bill who actually ran the test on my hydrants they only left me with a feeling of confidence that my hydrants were in good hands. :)
I would recommend Jason and Liberty Fire Solutions to anyone looking for a quality Sprinkler Inspection
confirmed with Stacy Bernhart for 7pm Fire Pump Inspection
confirmed with Chastity for afternoon -put systems on test. Sprinkler Inspection
confirmed with Matt Let the tech know they will have to either knock on door or call me at 814-505-6467 Sprinkler Inspection
confirmed with Bob for 8am Sprinkler Inspection
confirmed with Lisa for anytime. MUST BE DONE by the 4th Sprinkler Inspection
confirmed with Mike Kelly Fire Hydrant Inspection
confirmed with Giulio Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 3 year pressure test of the dry system per NFPA 25. NFPA 25 REQUIREMENTS FOR YEAR TESTING: NFPA 3.4.3.2.6 With the system at normal system pressure, shut off the air source (compressor) for 4 hours. If the low air pressure alarm goes off within this period, the air leaks shall be addressed. Notice of Three Year Dry Sprinkler System Pressure Test Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your
confirmed with John Hopkinson -TAKE LOANER COMPRESSIOR allow extra time during this annual due to compressor troubles. Sprinkler Inspection
go to front glass doors, use the buzzer on the left, go to front desk and ask for John. Sprinkler Service Call
CONFIRMED WITH ALLISON FOR 8AM 2 men needed- FULL trip on dry due Sprinkler Inspection
Confirmed with Tim for 1:00 Customer states fire pump is leaking water, please check it while there. Call Tim Allison on arrival 814-942-2480 He will meet you outside to use gym entrance. Fire Pump and Sprinkler Inspection
ANNUAL FIRE EXTINGUSIHER INSPECTION (6) SEMI-ANNUAL KITCHEN SUPPRESSION INSPECTION Inoperable Deficiency: Detection line failed No detection over 1 fryer Nozzles for fryers need moved to right and adjusted or move fryers to left No nozzle coverage for pizza oven ( replace 3N nozzles with 230 for pizza oven coverage) Replace detection line with ( all detection brackets are welded except for 5 ducts) Repipe nozzles over fryers for proper aim or move to appliances to right Detection bracket needed over 1 fryer Nozzle coverage for pizza oven Ansul detection bracket 50' cable 4 sticks 3/8 pipe 2 sticks conduit 4 1N nozzles 4 3/8 Tees 6 3/8 elbows 2 230 nozzles for cylinder on pizza oven and 2 fryers 3/8 hood seal
confirmed with Dan for 1/1:30 Sprinkler Inspection