13210 Dunnings Highway
Claysburg, PA 16625
814-239-3473

Local Reviews
for duncansville, pa

Rated 5.0 out of 5 stars based on 20 customer reviews

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fire safety

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service !

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service from Bill Beers

  • Overall Experience
  • Quality
  • Price
  • Convenience

Well done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service from and excellent service technician

Work was done in a timely manner by an excellent technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Friendly technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

5 STAR CUSTOMER SERVICE

GREAT COMMUNCATION AND GREAT CUSTOMER SERVICE.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for duncansville, pa

Bill  B.

Bill B. Job Checkin

confirmed with Dawn for 7am. Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Deficiency: Replace both sides of packing due smoke coming out of packing Aurora pump Type 6-481-1BB Serial # 12-2261268 Troy wants New bolt replacements for both sides and new packing


Jason  M.

Jason M. Job Checkin

Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Sprinkler Inspection


Bill  B.

Bill B. Job Checkin

NEED CINTAS PAPERWORK Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Special Hazards Inspection


Jason  M.

Jason M. Job Checkin

Semi-Annual Sprinkler System Inspection Deficiency: 1968 standard response sprinklers are due for 50 year UL testing 2- 165 degree upright 1/2” K factor 4.0 brass 2- 165 degree pendant 1/2” k factor 4.0 chrome Wet sprinkler with Alarm valve is due for the 5 year internal inspection and gauge replacement FDC hydrotest 2- water gauge. Steel threaded pipe 5 hours labor Deficiency: 1968 standard response sprinklers are due for 50 year UL testing 2- 165 degree upright 1/2” K factor 4.0 brass 2- 165 degree pendant 1/2” k factor 4.0 chrome Wet sprinkler with Alarm valve is due for the 5 year internal inspection and gauge replacement FDC hydrotest 2- water gauge. Steel threaded pipe Check valve is behind riser Need lift


Jason  M.

Jason M. Job Checkin

Annual Sprinkler System Inspection 6 Wet Risers. Deficiency: Antifreeze loop tested at 28 degrees due to no check valve 10 gallons antifreeze needs replaced Needs data sign 1 1/2 check valve 1- 1 1/2 Union Need threader and hydro pump


Jason  M.

Jason M. Job Checkin

Disarm then rearm system


Bill  B.

Bill B. Job Checkin

confirmed with Matthew Smearman Fire Hydrant Inspection


Jason  M.

Jason M. Job Checkin

Semi-Annual Clean Agent Suppression Inspection Equip Desc: KIDDE FENWAL 9300 -- SERVER ROOM Deficiency: Ceiling tiles are missing All ceiling tiles should have clips Install ceiling tiles with clips to hold tiles in place when system would discharge


Jarryd  R.

Jarryd R. Job Checkin


Bill  B.

Bill B. Job Checkin

USES CINTAS NOW Sprinkler Inspection


Jarryd  R.

Jarryd R. Job Checkin


Bill  B.

Bill B. Job Checkin

confirmed with John Annual Fire Pump & Sprinkler inspections Fire Pump and Sprinkler Inspection