13210 Dunnings Highway
Claysburg, PA 16625
814-239-3473

Local Reviews
for duncansville, pa

Rated 5.0 out of 5 stars based on 22 customer reviews

Excellent Service!

William Beers is always professional and very thorough!

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fire safety

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service !

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service from Bill Beers

  • Overall Experience
  • Quality
  • Price
  • Convenience

Well done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service from and excellent service technician

Work was done in a timely manner by an excellent technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Friendly technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for duncansville, pa

Bill  B.

Bill B. Job Checkin

confirmed with Dawn for 7:30. Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Annual Sprinkler System Inspection Deficiency: System is due for a 5 year internal inspection and gauge replacement System is due for 5 year FDC hydro test Storz connection 5 year internal inspection and gauge replacement 5 year FDC hydro test 2 water gauges Need lift for 25'


Bill  B.

Bill B. Job Checkin

confirmed with Wayne for 8am Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. Liberty Fire Solutions strongly recommends that your sprinkler system is repaired so that it will become compliant. The fire sprinkler system as-is will not work properly due to the above referenced deficiencies and may not extinguish, suppress or control a fire. This is a safety hazard and may contribute to damage or injury to your property and individuals in the event of a fire. Please contact me as soon as possible to review the attached proposal and schedule the


Jason  M.

Jason M. Job Checkin

1 5lb ext. cabinet needs replaced


Jason  M.

Jason M. Job Checkin

Portable Extinguishers Inspection


Bill  B.

Bill B. Job Checkin

confirmed with Amy for 9am. Maintenance, Jay, will meet you Sprinkler and Backflow Inspection


Bill  B.

Bill B. Job Checkin

Sprinkler and Backflow Inspection Quarterly Wet and Dry Sprinkler System Inspection Annual Backflow Inspection


Bill  B.

Bill B. Job Checkin

confirmed with John One head leaking, 5 need replaced due to rust at same time.


Bill  B.

Bill B. Job Checkin

confirmed with Dawn for 7am. Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Deficiency: Replace both sides of packing due smoke coming out of packing Aurora pump Type 6-481-1BB Serial # 12-2261268 Troy wants New bolt replacements for both sides and new packing


Jason  M.

Jason M. Job Checkin

Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Sprinkler Inspection


Bill  B.

Bill B. Job Checkin

NEED CINTAS PAPERWORK Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Special Hazards Inspection


Jason  M.

Jason M. Job Checkin

Semi-Annual Sprinkler System Inspection Deficiency: 1968 standard response sprinklers are due for 50 year UL testing 2- 165 degree upright 1/2” K factor 4.0 brass 2- 165 degree pendant 1/2” k factor 4.0 chrome Wet sprinkler with Alarm valve is due for the 5 year internal inspection and gauge replacement FDC hydrotest 2- water gauge. Steel threaded pipe 5 hours labor Deficiency: 1968 standard response sprinklers are due for 50 year UL testing 2- 165 degree upright 1/2” K factor 4.0 brass 2- 165 degree pendant 1/2” k factor 4.0 chrome Wet sprinkler with Alarm valve is due for the 5 year internal inspection and gauge replacement FDC hydrotest 2- water gauge. Steel threaded pipe Check valve is behind riser Need lift