Fire Pump and Sprinkler Inspection Confirmed with Wes


Bill  B.

Bill B. Job Checkin

Backflow Inspection Confirmed with Wendy for 8:30am.


Jason  M.

Jason M. Job Checkin

Annual Sprinkler Inspection


Bill  B.

Bill B. Job Checkin

Sprinkler Inspection NEW ACCOUNT! When your on the way please call Bob Rosage at 814-243-1434. Hes the on site property manager Confirmed with Eli


Bill  B.

Bill B. Job Checkin

confirmed with Deb for after Discovery Center Sprinkler Inspection


Bill  B.

Bill B. Job Checkin

Annual Backflow Inspection Backflow Inspection


Bill  B.

Bill B. Job Checkin

Sprinkler Inspection Annual Sprinkler System Inspection


Bill  B.

Bill B. Job Checkin

confirmed with Brenda Sprinkler Inspection


Bill  B.

Bill B. Job Checkin

Fire Pump and Sprinkler Inspection Confirmed with Deb for 8am -Set alarms off ASAP, (may be tours taking place starting at 10am).


Jason  M.

Jason M. Job Checkin

Special Hazards Inspection


Bill  B.

Bill B. Job Checkin

confirmed with Carol for 12noon. Annual Sprinkler inspection Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Sprinkler Inspection


Jason  M.

Jason M. Job Checkin

Sprinkler Inspection Deficiency: Both risers are due for 5 year internal inspection and gauge replacement FDC hydro test is due Need sign for control valve at FDC 5 year internal inspection ( 2 risers) 4 water gauges FDC hydro test ( no check valve, control valve at FDC in battery room) Need sign for Fire Company at FDC control valve ( Open to charge line)


Bill  B.

Bill B. Job Checkin

Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 5 year internal inspection and gauge replacement per NFPA 25. NFPA 25 REQUIREMENTS FOR 5 YEAR TESTING: 13.4.1.2 Alarm valves and their associated strainers, filters, and restricted orifices shall be inspected every 5 years unless tests indicate a greater frequency is necessary 13.4.2.1 Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely and are in good condition 14.2.1.1 An assessment of the int


Bill  B.

Bill B. Job Checkin

due date 2/16 Sprinkler Inspection