4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Job Locations
for niagara falls, on


Map of Niagara Falls ON
Shalik M.

Shalik M.


Job Checkin

Furnace Maintenance: Homeowner purchased #10 Humidifer pad. Humidifier solenoid valve is broken and needs to be replaced for proper flow. Turned off Humidifier water until fixed, because water is running regardless of furnace operation. Ventor motor venting glue has parted and needs to be fixed to stop the leak in top cabinet. Floor drain is cracked and causing water damage to surrounding area. Provided homeowner with two options. 1. Rerouting drain to other floor drain. 2. Flex tape and silicone on crack (band aide fix). Media filter was in opposite orientation, replaced and added air flow arrow for correct filter positioning. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently.