Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Precision tuneup on heating and cooling for Amana split system. Furnace is located in garage, remove 20 x 30 filter in ceiling and put in 16 x 25 filter within filter rack, found blower compartment, extremely covered in dust and debris, possibly from remodel highly recommend pulling/cleaning blower wheel in housing to prevent any issues with cooling/heating and burning out blower motorfrom excessive buildup. Zero carbon monoxide detected, found a starting amps as well as 45/5 MFD capacitor out of range recommend adding compressor saver kit to prevent further damage to compressor, assist compressor at start up and prolonged life of compressor, also recommend replacing 45/5 MFT capacitor to prevent any future breakdown into Weak capacitor. Verified refrigerant levels and took temperature split/rise and cycled equipment. Verified proper operation for water safety switch, cleared condensation line, washed condensing coil. Will send an estimate over for recommended repair repairs, at this t