Cost to install furnace and air conditioning. Remove heat pump and install AC.
Performed yearly maintenance and safety checks on Ducane AC system found 45/5 voltage absorption system reading 45*5. 103 inrush cleaned condenser. No further issues found at this time 20254 filter maintained by customer.
Performed yearly maintenance and safety checks on 3rd story 2013 tempstar furnace. Made call for heat. 54 ohm ignition system. Cleaned flame sensor and flu trap. Left new 16251 filter. Furnace ran with12.8% o2. 31 ppm co in flu. 40 degree deltat. Furnace cycled into second stage 9%o2. 21 ppm co in flu. 0 ppm co in supply. No issues found at this time. Also performed yearly maintenance and safety checks on main basement 22 Bryant system. Made call for heat found 54 degree deltat. 12.5%o2. 13 ppm co in flu. 0 ppm co in supply. Furnace cycled into second stage properly running with 9.75%o2. 0 ppm co in flu. 0 ppm co in supply. 20254 filter in need of replacement. Offered replacement with filter on van. Customer stated he will replace himself.
Responded to furnace no keeping up customer stated seems to take a while to cycle on. Found corrosion in drain line. Cleared trap. Furnace is running at this time. Before departure furnace faulted on inducer issue. Found voltage being sent to inducer but motor was not operating. Will call for pricing and availability in morning
Diagnose failing inducer motor on York furnace
Annual maintenance check on a Bryant furnace
0 Completion Notes: Perpfmred yearly maintenance and safety checks on Lennon 90% furnace. 6 ppm co in flu 12% o2 38 degree deltat. Furnace cycled into high stage properly running with 8.75%o2 0 ppm co in flu 48 ohm on ignition. No concerns at this time replaced 20-25-4 filter
Cost to replace furnace. Cost to install furnace and ac.
Customer stated buddy had looked at it. Said something to do with a sensor. Found furnace would cycle up to lighting but failed to light. Found 27 volts from board. Voltage dropped in 9 pin molex plug. Also found concerns with board being significantly corroded as well as blower motor. Water damage apparent throughout blower cabinet. During testing found technician could shut off HSI with probes in plug. Also found grinding noise coming from inducer motor. Informed customer of issues. Called for pricing and availability on control board and plug. Cannot get plug. Advised customer cannot get parts to fix system. And offered quote. Customer asked for ballpark. Ballparked 4000-5500 informed customer of 0 % financing options customer denied quote for new furnace. Collected service charge
Customer stated water running from Corner above furnace. Found drain clogged not allowing proper drainage. Offered to blow out current drain or replace due to customer stating ac is newer. Customer chose to blow out drain and sign up for yearly maintenance. Blew out drain. Poured roughly 30 oz water on drain to ensure proper disposal. Advised customer to annually pour vinegar in drain to help keep clear. Due to severity of clog advised customer to get vinegar to pour down drain for next 2-3 months then proceed annually. No further concerns
Performed yearly maintenance and safety checks on 2018 Bryants air handler heat pump. Found 15 KW heat strips pulling 20 A each. 55° temperature rise no signs of concern this point replacing number 10 water panel under service agreement no concerns
Performed yearly maintenance and safety checks on Goodman air handler heat pump found 10 kw heat kit running 20 amps each 50 degree delta t. No concerns at this time.
Performed yearly maintenance and safety checks on 2016 rtu system. Found 422 ppm co in flu. 10.3 %o2. Adjusted gas pressure to find co getting worse. Called for pricing of heat exchanger. Hm22 customer wants quote for new unit. Office will handle quote. Also performed yearly maintenance and safety checks on 01 concord unit. Found 10% o2 4 ppm co in flu 0 ppm co in supply. 111 stack temp. 46 degree delta t. No concerns at this time.
Performed yearly maintenance and safety checks on 2011 Bryant 90% furnace found issue with loud grinding noise from inducer motor. Called for pricing and availability. HM9A-E Customer chose option a. Retrieved part and performed repair. found 12% o2. 35 delta t. 25 ppm co. Adjusted gas pressure 10.6%o2 5 ppm co 50 degree delta t. 105 stack temp. No concerns at this point
Completed annual maintenance on a 2015 atlas butler furnace. During testing of the unit the technician found no electrical protection device, and air filter to be very dirty. Customer not interested in options today. Technician replaced customer provided air filter. Technician had to create inspection hole for analyzer. No issues at time of departure.