3981 Cleveland Ave
Columbus, OH 43224
614-475-1800

Local Reviews
for hilliard, oh

Rated 5.0 out of 5 stars based on 5 customer reviews

yearly service for furnace

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very friendly, very quick!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

Josh is always professional and friendly. I would want him on my team.


Response from Sears Heating & Cooling:

Thank you for the review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A/C Tune up

Joel came out and examined my A/C unit. In the vein of safety and the COVID19 pandemic, his service was contactless. He called me after to let me know that everything had checked out and that he left a filter on my front step. Thanks Joel!


Response from Sears Heating & Cooling:

Thank you for the great review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Trustworthy

On time and always does a great job!


Response from Sears Heating & Cooling:

Thank you for the review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hilliard, oh

Josh S.

Josh S. Job Checkin

Bryan 383 kav heat exchanger replaced in 2014. Bryant furnace from1994

Bryan 383 kav heat exchanger replaced in 2014. Bryant furnace from1994

Jamie S.

Jamie S. Job Checkin

There is a refrigerant leak in the condenser coil of the air condition. Proposed cost to replace air condition. Proposed cost to replace HVAC. Proposed cost to replace furnace

There is a refrigerant leak in the condenser coil of the air condition. Proposed cost to replace air condition. Proposed cost to replace HVAC. Proposed cost to replace furnace

Mike B.

Mike B. Job Checkin

Performing maintenance on a. 2016 rheem 2 stage gas furnace.m

Performing maintenance on a. 2016 rheem 2 stage gas furnace.m

Mike B.

Mike B. Job Checkin

Performing maintenance on a. 2009 Bryant high efficiency natural gas furnace.

Performing maintenance on a. 2009 Bryant high efficiency natural gas furnace.

Mike B.

Mike B. Job Checkin

Performing maintenance on a. 2017 Bryant gas furnace.


Mike B.

Mike B. Job Checkin

Performing maintenance on a 1987 Snyder general natural draft standing pilot gas furnace.

Performing maintenance on a 1987 Snyder general natural draft standing pilot gas furnace.

Mike B.

Mike B. Job Checkin

Bryant air conditioner. Found voltage enhancement system failed. Distribution center has badly pitted contacts and is burned. Went over options on page hn13. Customer went with hn13b. Completed repairs. Cycled system and completed performance testing. Temp drop is 18 degrees. Pressures are good. All okay at this time.

Bryant air conditioner. Found voltage enhancement system failed. Distribution center has badly pitted contacts and is burned. Went over options on page hn13. Customer went with hn13b. Completed repairs. Cycled system and completed performance testing. Temp drop is 18 degrees. Pressures are good. All okay at this time.

Mike B.

Mike B. Job Checkin

Performing maintenance on a 2014 Bryant t air conditioner.

Performing maintenance on a 2014 Bryant t air conditioner.

Wally T.

Wally T. Job Checkin

Replaced failed capacitor on a Goodman air conditioner


Jamie S.

Jamie S. Job Checkin

Cost to replace air condition

Cost to replace air condition

Mike B.

Mike B. Job Checkin

2018 Bryant air conditioner. Found system has a failed voltage enhancement system. Went over options on page hn13. Customer hn13b. Completed repairs and tested unit. Found system low on refrigerant. Went over options on page hj2. Customer decided he would like an estimate on full system replacement, josh scheduled between 2-4 pm.

2018 Bryant air conditioner. Found system has a failed voltage enhancement system. Went over options on page hn13. Customer hn13b. Completed repairs and tested unit. Found system low on refrigerant. Went over options on page hj2. Customer decided he would like an estimate on full system replacement, josh scheduled between 2-4 pm.

Josh S.

Josh S. Job Checkin

Replaced and and tested System is from2019 Goodman Found a finish basement with no water safety switch on indoor coil There is a two bends in the suction line but not completely kinked There is air flow leaks in downstairs throughout unfinished part of the duct work and where indoor coil and furnace meets. Furnace is from 1997kav She will speak to husband about repairs for future There can be a return added in finished part with panning and 7” 90’ with two collars Silicone on outdoor unit is not there and can have bugs enter I will go over repair options with office

Replaced and and tested 
System is from2019 Goodman 
Found a finish basement with no water safety switch on indoor coil 
There is a two bends in the suction line but not completely kinked 
There is air flow leaks in downstairs throughout unfinished part of the duct work and where indoor coil and furnace meets. 
Furnace is from 1997kav 
She will speak to husband about repairs for future 
There can be a return added in finished part with panning and 7” 90’ with two collars 
Silicone on outdoor unit is not there and can have bugs enter
I will go over repair options with office

Mike B.

Mike B. Job Checkin

Performing maintenance on a 2020 Goodman air conditioner.

Performing maintenance on a 2020 Goodman air conditioner.

Jamie S.

Jamie S. Job Checkin

Cost to replace air condition. Cost to replace HVAC system. Cost to install furnace and air condition

Cost to replace air condition. Cost to replace HVAC system. Cost to install furnace and air condition

Mike B.

Mike B. Job Checkin

2012 Maytag air conditioner. Rechecked everything on system again. Ran system for 10 minutes without a filter and let it stabilize. Put in customer filtrete filter and found it causing an airflow restriction dropping the pressures. Customer has been using these filters for several years. House is 27 years old and has never had the ducts cleaned. Customer mentioned pulling small pieces of drywall debris from a couple of his registers. If a large amount of dirt and debris has built up in ductwork this could be causing a sever restriction on airflow and with the filter as well. Recommend them to fresh air Corp for a duct cleaning and to use less restrictive filters. Merv 8 or less. Delta t is currently at 18 degrees. All okay at this time.