Work Performed: • Upon arrival, the tenant reported unusual noises from the furnace and noted that the blower motor seemed to cycle on and off irregularly. • Set the thermostat to cool, and the system activated. • Found a highly restricted air filter in the furnace — removed the filter to restore airflow. • Discovered a piece of side insulation had come loose and was obstructing the blower motor. • Removed the insulation to prevent further airflow restriction and blower interference. • Inspected the outdoor condenser and found the microchannel coil extremely dirty. • Removed the top panel and cleaned the coil thoroughly from the inside out. • Allowed the system to run for over 15 minutes and: • Verified proper refrigerant charge • Confirmed acceptable temperature split ⸻ System Condition Upon Completion: • Air Filter: Removed due to restriction • Insulation Obstruction: Cleared • Condenser Coil: Cleaned thoroughly • Blower Motor: Operating normally • Refrigerant Levels