Performed one-time tune-up on (2) 2006 Amana/Goodman r22 split systems (3.5 & 4 ton). Cleared condensation drains from attic (laundry room access). Changed (4) customer supplied filters (sizes noted). Cleaned out electrical compartments. Cleaned condenser coils. Honeywell Smart Color thermostats (9000) working properly. Checked amps, volts, start and run capacitors, refrigerant charges, and temperature splits . Systems are cooling properly at time of service. Homeowner noticed a few registers not putting out air, informed he has damper plates at some registers blocking airflow, recommended having Hyde’s remove registers and remove dampers then reinstall. Due to age of system and the, using r22 Freon, I recommended replacement of full systems before breakdown. Discussed heat pumps, refrigerant changes, etc. went over maintenance plan and benefits vs tuneup.