• Upon arrival, the client reported that the outdoor unit and air conditioning system were not working. • Went to the thermostat and set it to cool. The blower motor activated inside the home. • Inspected the condenser unit and found multiple component failures: • Blown high-voltage fuses • Failed hard start kit • Failed run capacitor • Discussed findings and repair options with the homeowner. • Client approved repairs. after repairs • Cycled the system on and verified proper start-up and operation. • Checked starting and running amperage — all within manufacturer specifications. ⸻ System Condition Upon Completion: • Hard Start Kit: Replaced • Run Capacitor: Replaced • High-Voltage Fuses: Replaced • Amperage Readings: Normal • Cooling Performance: Verified and operational • Overall Status: System is cooling properly at this time ⸻ Recommendations: • Due to the age and condition of the system, strongly recommend system replacement to ensure long-term reliability an