Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Performed annual heater maintenance on two American standards split systems FAU located in attic. Attic access located in master bedroom closet. Changed two 20 x 30 filter filters and washed washable filters for two mini splits located in garage and Casita. Checked amps,volts , capacitor, and cleaned burner compartment. Checked gas and static pressures. Also check temperature rise and all safety switches. Repaired and secured both flu pipes proper. Cycle system from thermostat. Thermostats are operational. Cycled both mini splits in heat mode. Both systems are heating properly. Found all electrical and safety components to be within manufactured specifications. All systems are operating and heating properly at time of service. Recommend installing water safety switch to prevent water damage to the home or equipment due to condensation back up or overflow. Also recommend installing Jones cleanout valves to properly flushed condensation lines and to ensure systems are draining properly.