Thor J.

Thor J.


Job Checkin

Upon arrival same issue was present. Breaker was tripped. Homeowner stated it cooled and then the next day it just stayed at indoor temp , never cooling down again. Found Honeywell P200 thermostat was now on Celsius and homeowner stated she never touched thermostat. Went into settings and found it was now reverted back to gas furnace configuration. Reprogrammed to heat pump, reversing valve o, Fahrenheit etc. put into cooling and while on delay getting proper 26vat reversing valve wire. Then when compressor delay was exited it went into cooling but made loud noise and pressures almost equalized then went into cooling. Wiring tight and secure and proper voltages , system has proper charge and pressure as well. Reversing valve appears to be sticking. Informed homeowner will follow up tomorrow morning. System is cooling now, 21 split, informed homeowner to leave thermostat on cooling mode and only to raise temperature if she want it to stop cooling but to not turn it off.