Job Checkin

Upon arrival, found thermostat for system serial number JM5S blank. Upon further inspection, found the water safety triggered, cleared condensation line at FAU and located outside termination to verify line has been properly cleared, removed all dust and debris away from outside termination covered by bushes and also cleared through outside termination and a secondary. Thermostat now has power restored, and system is cooling and operating. Informed client if issue presents itself, may need to move to condensate pump to prevent system, shutting off due to condensation back up triggering safety switch.