Would highly recommend. Very knowledgeable and great customer service.
We greatly appreciate the service given. It's allowed us to now know the problem and where to fix it.
Response from Northwest Fire Systems:
Thank you for the wonderful review and for taking the time to share your feedback.
Working with your office team was a huge challenge, but Marlon was very courteous and wonderful to have complete the work. Marlon would have received nothing but 5 stars. The office would be lucky to receive 2.
Three technician did the full service of our extinguishers and fire system.
Never had any issues working with Northwest Fire Systems since I took over my store. They are always friendly over the phone and in person. Whenever something is coming up to be taken care of, they contact well in advance so that you're able to plan around their service. They've even gone the extra mile in helping to troubleshoot any recurring issues I've had.
Allec was very friendly, skilled and worked with a big smile. Great man to have on your team. Never let him go! Gary Zink
I was not present during this service due to it being a holiday for our company. Would have preferred knowing ahead of time so dispatch staff would have been prepared and/or possibly change the date to when at least one manager would be onsite. Three stars due to lack of management on site to oversee what occurred.
Always enjoy working with the entire team at Northwest! Very neighborly!
Response from Northwest Fire Systems:
We appreciate the amazing 5 star review.
Annual Fire Alarm, Sprinkler, Backflow, and Fire Extinguisher Inspection
Conducted an annual fire prevention inspection to ensure compliance with safety standards. Examined all fire extinguishers, checking for proper pressure levels, intact seals, and expiration dates. Inspected smoke detectors and fire alarms, testing functionality and battery life. Evaluated emergency exit routes for obstructions and verified the condition of fire doors. Reviewed sprinkler systems, checking for leaks or corrosion, and tested the alarm valves. This thorough inspection helps maintain a safe environment and ensures all fire safety equipment is operational.
Replaced and programmed SK relay for Elevator Alt Recall. Verified that Elevator recalled. System is online and normal.
Annual Sprinkler, Backflow and Fire Extinguisher Inspection
Alarms were caused by the leak/water damage. (2) devices ((1) heat detector (1) smoke detector)to be replaced after repairs have been made. Wired devices through to clear panel and prevent alarms.
Ground Fault is on the SLC, traced GF to the Vault, vault had about 3 feet of water. Recommend return trip with pump and (2) Tamper switches incase the tampers are corroded. (2) tech. Needed for vault work.
Preformed 3 year full trip test on dry sprinkler system
I completed the installation of First Alert 9120B hardwired smoke detectors in a residential property. The project involved mapping out optimal locations for coverage, running electrical wiring to each designated spot, securely mounting the detectors, and connecting them to the home’s power supply with battery backup. I concluded with a functional test of each unit to ensure proper operation and interconnected alerts.